VIKING©
MODEL SQRG-12
VIKING ELECTRONICS, INC. HUDSON, WI 54016
SEQUENTIAL RING
GENERATOR
RJ21X RJ21X
J2 J1
TMS
CONTROL LINE
RESET
13.8V AC
1.25A MAX
POWER
1 2 3 4
1 2 3 4 ON
OFF
B. Installing the SQRG-12 with the TMS-12ARear View of the TMS-12A
Trunk Inputs of
PABX/KSU
Punch Down
Terminal Block with
Split Center
Row 3
SQRG-12
Pin, Color
26, W/BL
1,BL/W
27, W/O
2, O/W
28, W/G
3, G/W
29, W/BN
4, BN/W
30, W/S
5, S/W
31, R/BL
6, BL/R
32, R/O
7, O/R
33, R/G
8, G/R
34, R/BN
9, BN/R
35, R/S
10, S/R
36, BK/BL
11, BL/BK
37, BK/O
12, O/BK
50, V/S
Row 1
Ground/Loop
Start
C.O. Lines
1T
1R
2T
2R
3T
3R
4T
4R
5T
5R
6T
6R
7T
7R
8T
8R
9T
9R
10T
10R
11T
11R
12T
12R
*Earth Ground
Row 2
TMS-12A
Pin, Color
26, W/BL
1,BL/W
27, W/O
2, O/W
28, W/G
3, G/W
29, W/BN
4, BN/W
30, W/S
5, S/W
31, R/BL
6, BL/R
32, R/O
7, O/R
33, R/G
8, G/R
34, R/BN
9, BN/R
35, R/S
10, S/R
36, BK/BL
11, BL/BK
37, BK/O
12, O/BK
44, Y/BN
Row 5
SQRG-12
Pin, Color
38, BK/G
13, G/BK
39, BK/BN
14, BN/BK
40, BK/S
15, S/BK
41, Y/BL
16, BL/Y
42, Y/O
17, O/Y
43, Y/G
18, G/Y
44, Y/BN
19, BN/Y
45, Y/S
20, S/Y
46, V/BL
21, BL/V
47, V/O
22, O/V
48, V/G
23, G/V
49, V/BN
24, BN/V
Row 6
Ground/Loop
Start
Trunk Inputs
1T
1R
2T
2R
3T
3R
4T
4R
5T
5R
6T
6R
7T
7R
8T
8R
9T
9R
10T
10R
11T
11R
12T
12R
Row 4
Open
1. Wiring Table for the TMS-12A
Do not install bridging clips on any
connections which connect the two
halves of the punch down terminal
block. Bridge clips should only be
installed as a method of bypassing
equipment.
In order for the SQRG-12 to work
properly, the four-wire modular jack
must be installed between the TMS
CONTROL LINE on the SQRG-12 and
the SQRG jack on the TMS-12A.
Dip Switches for the TMS-12A
Loop Start
Switch
2
3
11
Position
Up
Down
Up
INPUTS/OUTPUTS
MUSIC
SQRG-12
TMS-RDMA
WARBLE
VOLUME
9 10 11 12
TMS-RDMA
USE ONLY
LISTED
CLASS 2
POWER
SOURCE
Viking Electronics, Inc.
Hudson, WI 54016
2. Notes
If the PABX does not recognize lines
on the TMS-12A as busy and call
crashing is observed, set up those
lines as “incoming only trunks” on the
PABX. If those lines must be used for
inbound and outbound calls, set DIP
switch 3 to on and switch 2 to off, on
the TMS-12A.
a.
b.
c.
1 - 12 C.O. Lines
Ground
Start
or
Ring All
Lines
Loop
Start
JP1
JP2
JP3
JP4
JP5
JP6
JP7
JP8
JP9
JP10
JP11
JP12
Note: For proper ground start operation,
JP1-JP12 must be removed in the
SQRG-12 as shown below.
V/S
Note: Earth Ground is required
in ground start applications
Dip Switches for the TMS-12A
Ground Start
Switch
2
3
11
Position
Down
Up
Up
* Earth Ground is only required in ground start or “mast/slave” applications.
Siemans # 566B3-50
Marconi # R66B3-50