| g. | Low voltage | g. | Check power supply |
| h. | Operating 60 Hz unit at 50Hz | h. | Use proper 60 Hz |
| i. | Sealed system problem | i. | Call service for checking loss of |
| j. | Undercharge or overcharge |
| refrigerant or restrictions |
| j. | Call service to add or remove | ||
|
|
|
| refrigerant |
|
|
|
|
|
7. House circuit tripping
| a. | Incorrect fuse or breaker | a. | Check for proper fuse or breaker |
| b. | Incorrect wirings | b. | Check for wirings and connections |
| c. | Failed components | c. | Call service |
|
|
|
|
|
8. Noisy operation
| a. | Mounting area not firm | a. Add support to improve installation | |
| b. | Loose parts | b. Check fan blades, bearings, cabinet | |
|
|
|
| washers, tubing contact and loose |
| c. | Compressor overloaded due to high |
| screws. |
| c. | Check for airflow blockage | ||
|
| ambient temperatures or airflow |
|
|
|
| restriction |
|
|
| d. | Malfunctioning components | d. | Call service for checking Internal |
|
|
|
| loose, inadequate lubrication and |
|
|
|
| incorrect wirings |
|
|
|
|
|
- 12 -