Status LEDs
There are two status LEDs on the front of your Micro Chip Display Projection TV.
Normal Operation
State | Power LED | Lamp LED | Description |
AC off | Not lit | Not lit | AC power not connected |
|
|
|
|
Standby mode | Orange | Not lit | AC power is connected and |
|
|
| your RPTV is in standby |
|
|
| mode. |
Blue | Orange Flashing | AC power is connected and | |
|
|
| the power button has just been |
|
|
| turned on. |
Cool down | Orange | Orange Flashing | Powering off. |
Operation mode Blue | Not lit | AC power is connected, the | |
|
|
| power button has been |
|
|
| pressed, and the lamp has |
|
|
| warmed up. |
Error Codes
Error | Power LED | Lamp LED | Description | |
Code | ||||
|
|
| ||
21 | Flashes blue twice, | Not lit | One of the cooling fans has failed. | |
then orange once. | See “Support” on page 49. | |||
|
| |||
|
|
| Lamp trouble or failure. Your RPTV | |
| Flashes blue three |
| automatically shut down and | |
32 | times, then orange | Flashing | restart itself. If this does not solve | |
| twice. |
| the problem, see “Support” on | |
|
|
| page 49. | |
|
|
| Hardware error. Shut off your | |
| Flashes blue five |
| RPTV, wait one minute, then | |
52 | times, then orange | Not lit | restart your RPTV. If this does not | |
| twice. |
| solve the problem, see “Support” | |
|
|
| on page 49. |