VIVOTEK
User's Manual - 169
49
trigger boot,
motion,
seq,
recnotify,
tampering,
vi,
volalarm
boot 6/6 Indicate the trigger condition:
“boot” = System boot
“motion” = Video motion detection
“seq” = Periodic condition
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
“volalarm” = Audio detection.
triggerstatus String[40] triggerstatus 6/6 The status for event trigger
vi <integer> 0 6/6 Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input.
The LSB indicates VI 0.
mdwin <integer> 0 6/6 Indicate the source window id of
motion detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1st window.
For example, to detect the 1st and 3rd
windows, set mdwin as 5.
mdwin0 <integer> 0 6/6 Similar to mdwin. The parameter
takes effect when profile 1 of motion
detection is enabled.
inter 1~999 1 6/6 Interval of snapshots in minutes.
This field is used when trigger
condition is “seq”.