Vulcan-Hart 2XGFGAS, F-32920, 2XG85F, 2XG65F warranty Serviceconnections

Models: 2XG65F 2XGFGAS 2XG85F F-32920

1 2
Download 2 pages 33.34 Kb
Page 2
Image 2
SERVICECONNECTIONS:

2XGF GAS FRYER / FRYMATE KLEENSCREEN PLUS® FILTRATION SYSTEM

IMPORTANT

1. A combination valve with pressure regulator is provided with this unit.

Natural Gas 4.0" (102 mm) W.C.

Propane Gas 10.0" (254 mm) W.C.

2. An adequate ventilation system is required for Commercial Cooking Equipment. Information may be obtained by writing to the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. When writing refer to NFPA No. 96.

3. All models require a 6" (152 mm) clearance at both sides and rear adjacent to combustible construction.

F/W

4.All models require a 16" (407 mm) minimum clearance to adjacent open top burner units.

5.This appliance is manufactured for commercial installation only and is not intended for home use.

SERVICECONNECTIONS:

P1 1/2" (13 mm) NPT common rear gas connection.

E1 120 volt, 60 Hz, 1 phase electrical connection (filter pump).

F/W Optional Heat Lamp 120 volt, 60 Hz, 1 phase electrical connection.

NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and specifications without notice.

F-32920 (10-07)

VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028

502-778-2791 QUOTE&ORDERFAX:1-800-444-0602

 

Printed On Recycled Paper