Maintenance Instructions | CLEANING |
CLEANING
Engine Air Cleaner System
There are two main components in the engine air cleaner system: a turbine precleaner and a Donald- son Radialseal™ air cleaner. Each component is checked, cleaned and maintained on a different schedule based on the filtering action required. Each component is serviced as follows:
Turbine Precleaner
The turbine precleaner is mounted on a remote air intake tube connected to the Donaldson air cleaner. A spinning fan driven by the intake airflow separates
dust from the air, giving the initial stage of air clean- ing. Dust particles are exhausted through a single small vent in the side of the housing. Since no dust is trapped, the precleaner operates without clean- ing. The only maintenance required is to check the operation of the internal fan every 100 hours. Verify operation:
1.Look into the exhaust vent while shining a light into the intake.
2.Start the engine and watch the fan begin to spin as the throttle is advanced.
If the fan is not spinning, service or replace the pre- cleaner as required.
Donaldson Air
Cleaner Cover
Air Restriction
Gauge
Turbine Precleaner | Hose |
| |
| Clamp |
Vacuator™
Valve
Precleaner Tube | Air Cleaner | |
Safety Filter Cartridge | ||
| ||
Hose | Donaldson | |
Air Cleaner | ||
Clamp | ||
|
Air Intake
Hose
Hose
Clamp
Engine
Engine Air Cleaner System Components
55