Maintenance Instructions

CLEANING

Donaldson Radialseal™ Air Cleaner

A remote mounted Donaldson Radialseal™ air cleaner provides the air filtering function. The paper filter element slides over an outlet tube inside the air cleaner canister with radial sealing action, eliminating the possibility of dust leaks due to improper filter installation. Intake design, internal baffling, and a Vacuator™ valve provide dust separation and automatic precleaning action. Daily or frequent servicing of the air cleaner is not required. Use the air restriction gauge on the air cleaner outlet to indicate when the air filter needs servicing -- a red flag will appear when the filter is overly restricting airflow into the engine.

IMPORTANT: Use only Donaldson air filter elements for replacement (Donaldson P822686 or Walker 5090-1). Aftermarket filters may not seal properly or filter efficiently.

Cover

Canister

Vacuator™

Valve

Radialseal™

Filter Element

Cover Latch

Air Cleaner Components

(shown with cover being removed)

IMPORTANT: The Donaldson air cleaner uses a dry paper-type filter element. NEVER apply oil to the paper element.

Push Button to Reset

Indicator After Service

Air Restriction

Gauge

Air Restriction Gauge Location

Clean and inspect the paper element after every 100 hours of service and replace the element yearly or after six (6) cleanings (or when dirty or dam- aged). More frequent cleaning may be required when operating in extremely dusty conditions as indicated by the air restriction gauge. Service the air cleaner as follows:

1.Release the top and bottom cover latches and remove the air cleaner cover. Wash the cover and Vacuator™ valve. Check that these com- ponents are in good condition. The Vacuator™ valve is subject to wear and deterioration and should be replaced yearly or when damaged. The lips of the valve should close and fit togeth- er; any cracks, deformation, or wear in the valve is cause for replacement.

2.Remove the filter element by pulling it out of the canister. There will be some initial resistance as the filter seal breaks loose and slides off of the outlet tube. Gently move the end of the filter up and down and side to side or twist to loosen the seal. Use gentle action to minimize the amount of dust dislodged as the filter is removed.

3.Clean the filter element using low pressure compressed air [less than 100 PSI (689 kPa)]. Blow out the filter from the interior of the ele- ment while turning the element.

NOTE: Washing the element in water or clean- ing solution is not recommended. Replace the element if it does not clean up with compressed air.