Waterford Precision Cycles Stainless Steel Box Hood manual Ventilation, Instructions For Assembly

Models: Stainless Steel Box Hood

1 7
Download 7 pages 5.6 Kb
Page 4
Image 4
VENTILATION

Digital display,displays the speed of the fan 1-6

Increases the speed of the fan (Max speed 6)

OFF delay switch, press once display flashes, fan switches off automatically after 10 minutes.

Light ON/OFF switch

VENTILATION

If there is an appliance fitted in the vicinity which requires air for combustion, additional air vents will be required to alleviate the possibility of spillage of products of combustion, from the appliance/flue while the fan is in operation. Refer to B.S. 5440 Part 2 & I.S. 813.

Where such an installation exists a test for spillage should be carried out with all appliances requiring air for combustion and all extraction fans running at maximum rate, (i.e. tumble dryers, extraction fans) with all external windows and doors closed.

If spillage occurs following the above operation, an additional air vent of sufficient size to prevent this occurrence should be installed.

INSTRUCTIONS FOR ASSEMBLY

The hood is designed to be wall mounted. Take the fixing brackets from the packaging and attach them to the fan unit as shown in Fig. 2 & 3. Remove the filters from the hood section as shown in (Fig. 5). Fix the hood section to the fan section using four 10mm screws (See Fig. 6). Insert the plug on the fan unit to the socket on the hood section. Position the hood in the desired position against the wall and mark the four positions for fixing the two fixing brackets. Drill four holes at the marked positions using a 6mm masonry drill bit and insert the rawl plugs into the holes. Screw the two bottom support screws half way into the rawl plugs and hook the hood assembly onto the screws. Fix the hood assembly to the wall by inserting the two top screws and tighten the bot- tom support screws. Attach the plastic coupling to the fan section using two 10mm screws (See Fig.4).

The steel ducting for the hood is to be fixed to the wall using the bracket supplied, the bracket is to be fixed nearest the ceiling and fixed to the end of the duct with slots in it.

THE MANUFACTURER WILL NOT BE RESPONSI- BLE IF THESE RECOMMENDATIONS AND INSTRUCTIONS REGARDING INSTALLATION, MAINTENANCE AND USE ARE NOT OBSERVED AND RESPECTED WHEN USING THE COOKER HOOD.

DIMENSIONS

Fig.1

Wall Fixing

Bracket

3

Page 4
Image 4
Waterford Precision Cycles Stainless Steel Box Hood manual Ventilation, Instructions For Assembly, Dimensions