Specifications
•(4)
•1⁄4 in. (6.35 mm) 316 SS tubing
•0.028 in. (0.710 mm) wall
•84 in. (213.36 cm) long
•Process temperatures to 350°F (177°C)
•Up to 1500 W
Options
•Single phase operation to 240V
•NEMA 1, 4 or 7 housings with and without sensors.
•Passivated or electropolished wetted surfaces
•Insulated body up to 400°F (204°C) operation
Dimensions
NEMA 1 and 4
5.07 in.
(129 mm)
4 in. |
|
|
|
|
|
| 2.30 in. |
|
| |
(113 mm) |
|
|
|
|
|
| (58 mm) |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2.03 in.
(52 mm)
0.5 in.
(13 mm)
NEMA 7
| 4.17 in. | |
| (106 mm) | |
| Ø2.50 in. | |
| (64 mm) | |
Ø1.25 in. | 3.43 in. | |
(87 mm) | ||
(31.75 mm) | ||
| ||
(2X) |
| |
0.5 in. NPT |
| |
(13 mm) | 1.3 in. | |
| ||
| (33 mm) | |
No Enclosure |
|
| 0.63 in. HTR | ||
0.74 in. T/C | (16 mm) |
| |
(19 mm) |
| 0.5 in. | |
|
| (13 mm) | |
0.313 in. |
|
| |
(8 mm) |
| 0.81 in. | |
|
| ||
|
| (21 mm) | |
5.75 in. | 4.75 in. | 6.43 in. | |
(121 mm) | (163 mm) | ||
(146 mm) | |||
|
|
Ø2 in. (51 mm)
Ordering Information
To order, complete the code number to the right with the information below.
W X 6 E 2 A - _ _ _ _ - _ _ _ _
Base Circulation Heater0.25in. O.D. (6.35 mm), 0.028 in. wall (0.71 mm), 316 SS tubing with 5⁄8 in. (16 mm) dia. cartridge heater with 36 in. (914 mm) Teflon® leads.
No housing
Heater Wattage300A = 120V, 300 W
300B = 120V, 1500 W
300C = 240V, 300 W
300D = 240V, 500 W
300E = 240V, 750 W
300F = 240V, 1000 W
300G = 240V, 1200 W
300H = 240V, 1500 W
300J = 208V, 1125 W
300K = 208V, 900 W
300L = 208V, 750 W
300M = 208V, 565 W
Enclosures and Sensors00 = No sensor or enclosure
0J = Type J T/C in casting, no housing
0K = Type K T/C in casting, no housing
S0 = NEMA 1 housing, no sensor
SJ = NEMA 1 housing with Type J sensor in casting SK = NEMA 1 housing with Type K sensor in casting W0 = NEMA 4 housing, no sensor
WJ = NEMA 4 housing with Type J sensor in casting WK= NEMA 4 housing with Type K sensor in casting E0 = NEMA 7 housing, no
EJ = NEMA 7 housing with Type J sensor in heater, non standard delivery
EK = NEMA 7 housing with Type K sensor in heater, non standard delivery
High Limits (Only available with no housing option)00 = None
01 = Snap action high limit set at 260˚F (127°C) 02 = Snap action high limit set at 500˚F (260°C)
AccessoriesPair high pressure compression fitting -
Maximum process temperature 350°F (177°C)
Maximum water flow rate is 0.75 GPM
Consult factory for gas applications
Teflon® is a registered trademark of E.I. du Pont de Nemours & Company.
1.19 in. |
|
|
|
(30 mm) | 2.44 in. | (6X) | 0.38 in. |
| (62 mm) |
| (10 mm) |
|
| 0.63 in. |
|
|
| (16 mm) |
|
1.38 in. |
| 1.25 in. |
|
(35 mm) |
| (32 mm) |
|
1.13in. (29 mm)