Quote and Ordering Information

Tube Flexing

 

For a quote, please request, fill out and return a FREEFLEX

• Static (to route around components in system)

 

• Dynamic (subject to more continuous flexing)

 

application data sheet.

 

 

• Occasional, frequent or continuous

 

To order, please specify:

 

Note: Minimum recommended flexing radius

 

Fluid Type

 

 

132 in. (0.792 mm) I.D. x 116 in. (1.59 mm) O.D. Teflon® 1 in. (25 mm)

Inlet Temperature

 

 

116 in. (1.59 mm) I.D. x 18 in. (3.18 mm) O.D. Teflon®

112 in. (38 mm)

Outlet Temperature

 

 

18 in. (3.18 mm) I.D. x 316 in. (4.76 mm) O.D. Teflon®

2 in. (51 mm)

Flow Rate

 

 

316 in. (4.76 mm) I.D. x 14 in. (6.35 mm) O.D. Teflon®

3 in. (76 mm)

Voltage - Typically less than 36 volts

Heater Leads

 

• One at each end

 

Watts/ft - See chart below for typical values

 

• Both at one end

 

Maximum Allowable Outside Surface Temperature

 

• Standard lead insulation (UL® Style 1180 white Teflon®)

Tube Size

 

 

 

 

• Other insulation (specify)

 

132 in. (0.792 mm) I.D. x 116 in. (1.59 mm) O.D.

 

116 in. (1.59 mm) I.D. x 18 in. (3.18 mm) O.D.

Heater Lead Length

 

1

3

16 in. (4.76 mm) O.D.

• Standard 12 in. (305 mm) w/customer end stripped/tinned

8 in. (3.18 mm) I.D. x

 

1

 

316 in. (4.76 mm) I.D. x 14 in. (6.35 mm) O.D.

2 in. (13 mm)

 

• Other (specify size)

 

 

• Other (specify)

 

 

 

Heater Lead Exit Direction

 

Tube Material

 

 

 

 

 

• Inboard/outboard

 

Teflon® (standard)

 

 

 

 

 

Temperature Sensor

 

Silicone rubber

 

 

 

 

 

• Standard thermocouple (#30 AWG Teflon® - Type J)

Others upon request

 

 

• Thermistor (specify) 10K￿ at 25˚C (72˚F) standard

Tube Length - 12 to 120 in. (305 to 3048 mm) typical

• Other temperature sensors size/types (specify)

 

• Total

 

 

 

 

 

• Sense heater element or tube temperature

 

• Heated

 

 

 

 

 

Sensor Lead Exit Direction

 

• Unheated (specify)

 

 

 

 

 

• Inboard/outboard

 

Tube Fittings

 

 

 

 

 

Temperature Sensor Lead Length

 

• No fittings (1 in. (25 mm) bare tubing at each end)

• Standard 12 in. (305 mm)

 

• Other (specify)

 

 

• Other (specify)

 

 

 

 

 

 

Water Temperature Rise/Length Versus Flow Rate Versus Watt Density

Temperature Rise

(˚F/Foot)

Water

 

Water Temperature Rise/Foot vs. Flow Rate vs. Watt Density (1/16 in. (1.59 mm) I.D. Tube)

90

80

70

60

 

 

 

 

 

 

W/ft

W/m

50

 

 

 

 

 

 

 

 

 

 

 

 

50.0

164

40

 

 

 

 

 

 

37.5

123

30

 

 

 

 

 

 

25.0

82

 

 

 

 

 

 

12.5

41

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

10

20

30

40

50

60

70

80

90

 

 

 

Flow Rate of Water (mL/Minute)

 

 

164

 

 

146

 

Water

128

 

109

(˚C/Meter)

Temperature

55

91

 

 

73

 

 

36

 

Rise

 

 

18

 

 

0

 

 

100

 

 

Water Temperature Rise °F/Foot

 

Flow Rate (mL/minute)

 

W/ft

10

30

50

100

50.0

82

29

19

10

37.5

64

22

14

7

25.0

41

16

10

5

12.5

22

8

5

3

Water Temperature Rise °C/Meter

 

Flow Rate (mL/minute)

 

W/m

10

30

50

100

164

149

52

35

18

123

116

40

26

13

82

75

29

18

9

41

40

15

9

5

FREEFLEX Outside Diameter Temperature Versus Watts/Length

O.D. Temperature vs. Watts/Meter

O.D. Temperature (˚F)

350

 

 

 

1.5

3.0

4.6

6.1

 

 

 

7.6

 

 

 

 

177

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

149

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.D.O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

121

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

93

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O.D. Temperature vs. Watts/Unit Length

 

 

 

 

 

 

(˚C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry Tube - No Flow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

10

15

20

 

 

 

25

30

 

O.D. Temperature vs. Watts/Foot

W/ft W/m

O.D. Temperature

 

 

°C

(°F) (Ambient)

0

0

21

(70)

5

1.5

60

(140)

10

3.0

99

(210)

15

4.6

129

(265)

20

6.1

154

(310)

25

7.6

171

(340)

To be automatically connected to the nearest North American Technical and Sales Office:

1-800-WATLOW2 • www.watlow.com • info@watlow.com

International Technical and Sales Offices: Australia, +61-3-9335-6449China, +86-21-3950-9510France, +33 (0) 3073-2425Germany, +49 (0) 7253-9400-0Italy, +39 (0) 2 458-8841Japan, +81-3-3518-6630Korea, +82-2-575-9804Malaysia, +60-3-7980-7741Mexico, +52 (442) 217-6235Shanghai, +86-21-3950-9504Singapore, +65-6777-1266Spain, +34 91 675 1292 • Sweden, +46 35-27-11-66Taiwan, +886-7-288-5168United Kingdom, +44 (0) 115-964-0777