Symptoms

Possible Cause(s)

Suggested Remedies

Pump shuts off

1.

Excessive water temperature

1.

Pump should not be used for water above 120º F

and turns on

2.

Switch

2.

Replace switch kit

independently

3.

Switch Obstruction

3.

Remove obstruction to ensure free motion of switch

of switch (trips

 

 

 

 

 

 

 

 

thermal overload

4.

Obstruction in discharge pipe

4.

Remove obstruction in discharge piping

protection)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump may start unexpectedly.

Disconnect power supply before servicing.

Pump operates noisily or vibrates excessively

Pump will not shut off

5. Low line voltage

1.Worn bearings

2.Debris in impeller cavity or broken

3.Piping attachments to building structure too rigid or too loose

1.Switch

2.Switch obstructions

3.Restricted discharge (obstruction in piping)

5a.Contact an electrician.

5b.Do not use an extension cord.

1.Replace pump

2.Remove screen and volute, clean impeller and/or replace impeller

3.Install rubber coupling (available at local hardware stores) to isolate pump vibration from discharge plumbing

1.Replace with switch kit

2.Remove obstruction to ensure free motion of switch

3.Remove obstruction from discharge piping

Pump operates but delivers little or no water

4.

Excessive inflow or pump not

4.

Recheck all sizing calculation to determine proper pump size

 

properly sized for application

 

 

1.

Low line voltage

1a.Contact an electrician

 

 

1b.Do not use an extension cord.

2.

Inlet screen clogged

2.

Remove debris

3.

Broken impeller or debris in

3.

Remove screen and volute , clean impeller and/or replace

 

impeller cavity

 

impeller

5.

Pump not properly sized for

5.

Recheck all sizing calculations to determine proper pump size

 

application

 

 

6.

Check valve stuck closed or

6.

Remove and examine check valve for proper installation and

 

installed backwards

 

free operation

7.

Shut off valve closed

7.

Open valve

Printed on 100% Recycled Paper