GAS INSTRUCTIONS

 

 

9

 

 

 

 

 

Check:

SUMMIT® A

 

 

 

1)

Hose connection.

(2)

 

(1)

2)

Gas line to manifold connections.

 

 

 

 

 

WARNING: If there is a leak at connection (1, or 2),

 

 

 

 

 

retighten the fitting with a wrench and recheck for

 

 

 

 

 

leaks with soap and water solution.

 

 

 

 

If a leak persists after re-tightening the fitting, turn

 

 

 

 

OFF the gas. DO NOT OPERATE THE GRILL. Contact

 

 

 

 

the Customer Service Representative in your area using the

 

 

 

 

contact information on our web site. Log onto www.weber.com®.

 

 

 

 

3)

Regulator to cylinder connection.

 

 

 

 

4)

Hose to regulator connection.

 

 

 

 

5)

Valves to manifold connections.

 

 

 

 

 

WARNING: If there is a leak at connections (3,4, or 5),

 

 

 

 

turn OFF the gas. DO NOT OPERATE THE GRILL. Contact

 

 

 

 

the Customer Service Representative in your area using the

 

 

 

 

contact information on our web site. Log onto www.weber.com®.

 

(5)

 

 

When leak checks are complete, turn gas supply OFF at the source and

 

 

 

rinse connections with water.

 

 

(4)

(3)

 

 

 

 

 

 

 

 

 

Check:

1)Hose connection.

2)Gas line to manifold connections.

3)I.R. Burner gas line connection.

WARNING: If there is a leak at connection (1,2, or 3), retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after re-tightening the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www. weber.com®.

4)Side burner hose to manifold connection

5)Side burner hose to side burner connection, and sideburner valve to orifi ce

6)Regulator to cylinder connection.

7)Hose to regulator connection.

8)Valves to manifold connections.

WARNING: If there is a leak at connections (4,5,6,7, or 8), turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

SUMMIT® B, D

 

(2)

(1)

(3)

 

 

(4)

(8)

 

(7)

(6)

Page 9
Image 9
Weber 38026 manual GAS Instructions