14 | SIDE BURNER TROUBLESHOOTING |
| ||
|
|
|
|
|
|
|
|
|
|
PROBLEM |
| CHECK | CURE |
|
|
|
|
|
|
Side Burner does not light. |
| Is gas supply off? | Turn supply on. |
|
|
|
|
|
|
Flame is low in HIGH position. |
| Is the fuel hose bent or kinked? | Straighten hose. |
|
|
|
|
|
|
|
| Is LP fuel low or empty? | Refi ll LP cylinder. |
|
|
|
|
|
|
|
| The excess fl ow safety device, which | To reset the excess flow safety device turn all burner control |
|
|
| is part of the barbecue to cylinder | knobs and the cylinder valve OFF. Disconnect the regulator |
|
|
| connection, may have activated. | from the cylinder. Turn burner control knobs to HIGH. Wait at |
|
|
|
| least 1 minute. Turn burner control knobs OFF. Reconnect the |
|
|
|
| regulator to the cylinder. Turn cylinder valve on slowly. Refer to |
|
|
|
| “Lighting Instructions”. |
|
|
|
|
|
|
Push button ignition does not work. |
| Does burner light with a match? | If match lights burner, check igniter (see below). |
|
|
|
|
|
|
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your region using the contact information sheet provided with your manual.
SIDE BURNER MAINTENANCE
WARNING: All gas controls and supply valves should be in the OFF position.
Make sure wire is connected between the igniter and electrode. Spark should be a white/blue color, not yellow.
1)Igniter Wire
2)Burner
(3)
Side Burner Grate
Side Burner Cap
Side Burner Ring & Head
Igniter Electrode
Control Knob
Igniter