Weber 55024 manual Reinstall control panel after checking for gas leaks

Models: 55024

1 26
Download 26 pages 24.16 Kb
Page 16
Image 16

Check:

1)Hose to manifold connection

2)Manifold to side burner hose connection

WARNING: If there is a leak at connection(1),

retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

3)Side burner hose to side burner connection

4)Valves to manifold connections

5)Hose to quick disconnect connection

WARNING: If there is a leak at

connections(2),(3),(4) or(5), turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

(1)

(2)

(3)

(4)

(5)

Reinstall control panel (after checking for gas leaks)

(1)Set the control panel in place over both sides of the frame. Hold the crossover ignition button up while setting the control panel in place.

(2)Line up the control panel with the white plastic plugs in the frame brace. Insert screws and tighten with a Phillips screwdriver until snug. Do not overtighten.

(3)Push each of the burner control knobs onto their valve.

(4) Reinstall Side Burner cover.

C-4

Page 16
Image 16
Weber 55024 manual Reinstall control panel after checking for gas leaks