Connect side burner to manifold WARNING: Make sure gas supply is off.
Connect the side burner hose as follows:
1)Slide back the collar of the quick disconnect on the manifold.
2)Push the male fitting of the side burner hose into the quick disconnect, and maintain pressure. Slide the collar closed.
Quick disconnect will be engaged.
Check to be sure the side burner valve is OFF. Push the side burner control knob down and turn it clockwise. If it doesn’t turn, the valve is OFF. If it does turn, continue turning it clockwise until it stops, then the burner valve is OFF.
(1)
(2)
Install Gas Supply
General Specifications for Piping
Note - Contact your local municipality for building codes regulating outdoor gas barbecue installations. In absence of Local Codes, you must confirm to the latest edition of ANSI Z223.1. WE RECOMMEND THAT THIS INSTALLATION BE DONE BY A PROFESSIONAL.
Some of the following are general requirements taken from ANISI Z223.1 latest edition for complete specifications.
■This barbecue is designed to operate at 7 inches of water column pressure (.2526 psi).
■A manual
■An additional manual
■The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The quick disconnect fitting is a
■The quick disconnect fitting can be installed horizontally, or pointing downward. Installing the fitting with the open end pointing upward can result in collecting water and debris.
■The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fitting clean while disconnected.
■Pipe compound should be used which is resistant to the action of natural gas when connections are made.
■The outdoor connector must be firmly attached to rigid, permanent construction.
WARNING: Do not route the 12 foot hose under a deck. The hose must be visible.
| Gas supply |
Inside wall |
|
Outside wall |
|
| Shut off |
Quick Disconnect | Locking shut off |
|