Gas Instructions

Check that all burner valves are off

Valves are shipped in the OFF position, but you should check to be sure that they are turned OFF. Check by pushing down and turning clockwise. If they do not turn, they are off. Proceed to the next step. If they do turn continue turning them clockwise until they stop, then they are off. Proceed to the next step.

Remove control panel and burner control knobs You will need: Phillips screwdriver.

1)Remove control knobs.

2)Remove screws through slots in trim with a Phillips screwdriver.

3)Pull up igniter button until it sticks in the up position and remove control panel from grill.

(1)

Check the flexible hose to manifold connection See Page C-3

The Natural gas hose has been attached during the manufacturing process. We do recommend that the hose to gas manifold connection be leak tested, following guidelines in this Owners Guide, prior to barbecue operation.

Check:

1) Hose to manifold connection.

￿WARNING: If there is a leak a connection(1), retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

(2)

(3)

(1)

4) Replace control panel when Leak Check is completed.