Side Burner Troubleshooting

Problem

Check

Cure

Side Burner does not light.

Is gas supply off?

Turn supply on.

 

 

 

Flame is low in HIGH position.

Is the fuel hose bent or kinked?

Straighten hose.

 

 

 

Flame is very yellow in

Inspect the Weber® Insect / Spider

Clean Weber® Insect / Spider

conjunction with the smell of gas,

Screens for possible obstructions.

Screens (See section “Annual

 

(lockage of holes.)

Maintenance”)

OR

 

 

Burner makes popping noise in

 

 

conjunction with the smell of gas.

 

 

 

 

 

Push button ignition does not

Does burner light with a match?

If match lights burner, checkigniter

work.

 

(see below).

 

 

 

Side Burner maintenance

WARNING: All gas controls and supply valves should be in the OFF position.

Check igniter: Remove side burner cover. To remove side burner cover, remove control knob and screws that hold cover to bottom(1).

(1)

 

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3)

Make sure wire is connected between igniter and electrode. Check that igniter lock nut is tight.

Note: If the igniter works loose, carefully tighten the igniter lock nut with an adjustable wrench or pliers.

Adjust igniter electrode to burner. Gap should be 1/8 to 3/ 16 inch from tip of electrode to burner. Spark should be a white/blue color, not yellow.

1)Igniter

2)Igniter Wire

3)Venturi/Burner

4)1/8 to 3/16 inch gap between electrode and burner

(4)

D-5

Page 27
Image 27
Weber 55768 manual Side Burner Troubleshooting, Side Burner maintenance