i)Reinstall the Spider Stopper Guards. Slightly rotate the Spider Stopper Guards so that the seams are in line with the Venturi fins. There should be no gaps in the seams or in the fit around the burners and valves. Figure 19.

Check fit around valve

Venturi fin

Check fit around burner

Figure 19

CAUTION: If the Spider Stopper Guards do not fit tightly, contact Weber-Stephen Customer Service.

WARNING: After reinstalling the gas lines, they should be leak checked with a soap and water solution before using the barbecue. (See Step“Check for gas leaks”).

Crossover Ignition System Operations

If the Crossover Ignition System fails to ignite the Front burner, light the Front burner with a match. If the Front burner lights with a match, then check the Crossover Ignition System.

Check that both the white and black ignition wires are attached properly. Figure 20.

White wire

Black wire

Figure 20

Check that the Crossover Ignition button pushes the igniter (button) down, and returns to the up position.

Check to see if the igniter is loose in the frame. Tighten if necessary; see Step “Install igniter” for correct procedure.

If the Crossover Ignition System still fails to light, contact Weber-Stephen Customer Service.

31

Page 31
Image 31
Weber 730 Series owner manual Crossover Ignition System Operations