Weber 89796 manual 12OPERATING, DOT 4BA240

Models: 89796

1 44
Download 44 pages 54.48 Kb
Page 12
Image 12
12OPERATING

12OPERATING

WARNING: Replacement LP tanks must match the regulator connection supplied with this barbecue.

Liquid Propane Cylinder requirements

Check to be sure cylinders have a D.O.T. certifi cation (1), and date tested (2) is within fi ve years. Your LP gas supplier can do this for you.

All LP tank supply systems must include a collar to protect the cylinder valve.

The LP cylinder must be a 20-lb. size approximately (18¼ inches high, 12¼ inches in diameter).

The cylinder should be constructed and marked in accordance with the

Specifi cations for LP - Gas Cylinders of the U.S. Department of Transportation (D.O.T.) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes or Transportation of Dangerous Goods; and Commission, as applicable.

In Canada

Liquid Propane Cylinder requirements

Note: Your retailer can help you match a replacement tank to your barbecue.

The LP cylinder must be constructed and marked in accordance with the specifi cations for LP gas cylinders, T.C.

(1)

DOT 4BA240

00/02

(2)

SIDE BURNER LIGHTING INSTRUCTIONS

DANGER

Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

1)Open the side burner lid.

2)Check that the side burner valve is turned OFF. (Push knob in and turn clockwise to ensure that it in the off position.)

WARNING:

The burner control knob must be in the OFF position before turning on the liquid propane cylinder valve. If it is not in the OFF position, when you turn on the LP cylinder valve, the “excess gas flow control” feature will activate, limiting the flow of gas from the LP cylinder. If this should occur, turn OFF the LP tank valve and burner control knobs. Then start over.

3)Turn the LP tank valve on (turn counter-clockwise).

4)Push in and turn the side burner control valve to START/HI.

5)Push igniter button and hold until burner ignites. You will hear the igniter sparking.

CAUTION: Side burner flame may be difficult to see on a bright sunny day.

WARNING: If the side burner does not light:

1)Turn OFF the side burner control valve.

2)Wait 5 minutes to let the gas clear before you try again or try to light with a match.

DOT 4BA240

 

Manual backgroundManual background 

TO EXTINGUISH

Push down and turn each burner control knob clockwise to the OFF position. Turn gas

supply OFF at the source.

WWW.WEBER.COM®

Page 12
Image 12
Weber 89796 manual 12OPERATING, DOT 4BA240