![12OPERATING](/images/new-backgrounds/53991/5399123x1.webp)
12OPERATING
•Be sure the regulator is mounted with the small vent hole pointed downward so that it will not collect water. This vent should be free of dirt, grease, bugs etc.
•The gas connections supplied with your Weber® gas barbecue have been designed and tested to meet 100% CSA and ANSI requirements.
WARNING: Replacement LP tanks must match the regulator connection supplied with this barbecue.
LIQUID PROPANE CYLINDER REQUIREMENTS
•Check to be sure cylinders have a D.O.T. certification (1), and date tested (2) is within five years. Your LP gas supplier can do this for you.
•All LP tank supply systems must include a collar to protect the cylinder valve.
•The LP cylinder must be a
•The cylinder must be constructed and marked in accordance with the Specifications for LP - Gas Cylinders of the U.S. Department of Transportation (D.O.T.) or the National Standard of Canada,
(1)
DOT 4BA240
00/02
(2)
IN CANADA
LIQUID PROPANE CYLINDER REQUIREMENTS
Note: Your retailer can help you match a replacement tank to your barbecue.
•The LP cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders, T.C.
SIDE BURNER LIGHTING INSTRUCTIONS
DANGER
Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive
1)Open the side burner lid.
2)Check that the side burner valve is turned OFF. (Push knob in and turn clockwise to ensure that it in the off position.)
WARNING:
The burner control knob must be in the OFF position before turning on the liquid propane cylinder valve. If it is not in the OFF position, when you turn on the LP cylinder valve, the “excess gas flow control” feature will activate, limiting the flow of gas from the LP cylinder. If this should occur, turn OFF the LP tank valve and burner control knobs. Then start over.
3)Turn the LP tank valve on (turn
4)Push in and turn the side burner control valve to START/HI.
5)Push igniter button and hold until burner ignites. You will hear the igniter sparking.
CAUTION: Side burner flame may be difficult to see on a bright sunny day.
WARNING: If the side burner does not light:
1)Turn OFF the side burner control valve.
2)Wait 5 minutes to let the gas clear before you try again or try to light with a match.
TO EXTINGUISH
Push down and turn each burner control knob clockwise to the OFF position. Turn gas supply OFF at the source.
WWW.WEBER.COM®