Step 14

Check that all burner valves are off

Valves are shipped in the OFF position, but you should check to be sure. Put the knob on each valve. Check by pushing down and turning clockwise. If they do not turn they are off, proceed to the next step. Figure 15.

Route the hose so it will not interfere with the scale indicator rod.

The hose and regulator are connected in the following manner:

Slide back the collar of the quick disconnect on the tank valve. Push the male fitting of the regulator into the quick disconnect, and maintain pressure. Slide the collar closed. Figure 17 (a). Figure 17 (b) shows the quick disconnect engaged and various components of the tank and regulator. Regulator vent hole should be at 3, 6, or 9 o'clock. It should not be pointed up. Figure 17 (c).

Figure 15

(a)

Collar

Step 15

Connect LP tank

mWARNING: Make sure that the LP tank valve is closed. Close by turning clockwise.

Hook the LP tank onto the fuel scale. Loosen the tank lock wing nut. Swing the tank lock down. Tighten the wing nut. Figure 16.

E

Tank lock

 

wing nut

F

 

Male fitting

Hose (b)

Tank valve

Regulator

Regulator vent

Valve handwheel close clockwise

Pressure relief valve

Tank

Figure 16

Quick disconnect engaged

(c)

Turn so regulator vent does not collect water

Figure 17

16

Page 16
Image 16