Weber SILVER A Crossover Ignition System Operations, Fit tightly, contact the Customer Service

Models: SILVER A

1 29
Download 29 pages 6.19 Kb
Page 28
Image 28

9) Reinstall the Spider Stopper Guards. Slightly

Crossover® Ignition System Operations

rotate the Spider Stopper Guards so that the

If the Crossover Ignition System fails to ignite the Left

seams are in line with the Venturi fins(1). There

burner, light the Left burner with a match. If the Left

should be no gaps in the seams or in the fit around

burner lights with a match, then check the Crossover

the burners(2) and valves(3).

Ignition System.

 

Check that both the white(1) and black(2) ignition

 

wires are attached properly.

(1)

 

 

(3)

 

 

(2)

(1)

(2)

m CAUTION: If the Spider Stopper Guards do not

 

 

fit tightly, contact the Customer Service

Check that the Crossover Ignition button pushes the

Representative in your region using the contact

igniter (button) down, and returns to the up position.

information sheet provided with your manual.

Check to see if the igniter is loose in the frame.

m WARNING: After reinstalling the gas lines, they

Tighten if necessary; See Step “Install igniter” for

should be leak checked with a soap and water

correct procedure.

 

solution before using the barbecue. (See Step:

 

If the Crossover Ignition System still fails to light,

“Check for gas leaks.”)

Contact the Customer Service Representative in your

 

 

region using the contact information sheet provided

 

with your manual.

 

D-7

Page 28
Image 28
Weber SILVER A manual Crossover Ignition System Operations, Fit tightly, contact the Customer Service, Check for gas leaks