Weed Eater 96112010100, WE18C, 438181 manual Pre-Operation, Minimum Gauge For Extension Cords Awg

Models: 96112010100 438181 WE18C

1 16
Download 16 pages 38.98 Kb
Page 5
Image 5
PRE-OPERATION

PRE-OPERATION

POLARIZED APPLIANCE

CONNECTIONS

To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other) and will require the use of a polarized extension cord.

The appliance plug will fi t into a polar- ized extension cord only one way. If the plug does not fi t fully into the extension cord, reverse the plug. If the plug still does not fi t, obtain a correct polarized extension cord.

A polarized extension cord will require the use of a polarized wall outlet. This plug will fi t into the polarized wall outlet only one way. If the plug does not fi t fully into the wall outlet, reverse the plug. If the plug still does not fi t, contact a quali- fi ed electrician to install the proper wall outlet.

IMPORTANT: Do not change the equipment plug, extension cord receptacle, or extension cord plug in any way.

2-prong

Properly grounded

plug

extension cord

MINIMUM GAUGE FOR EXTENSION CORDS (AWG) CAUTION: In all cases, make certain the receptacle in question is properly grounded. If you are not sure, have a certifi ed electrician check the receptacle.

This mower is “Double Insulated”.

Manual background WARNING: This mower is for outdoor use only. Do not expose to rain or use in damp locations.

Avoid Dangerous Environment – Don’t use lawn mowers in damp or wet loca- tions.

Don’t Use In Rain.

Keep Children Away – All visitors should be kept a safe distance from work area.

Dress Properly – Do not wear loose clothing or jewelry. They can be caught in moving parts. Use of rubber gloves and footwear is recommended when working outdoors.

Use Safety Glasses – Always use face or dust mask if operation is dusty.

Use Right Appliance – Do not use lawn mower for any job except that for which it is intended.

Ground Fault Circuit Interrupter (GFCI) protection should be provided on the circuit(s) or outlet(s) to be used for the lawn mower. Receptacles are available having built-in GFCI protection and may

be used for this measure of safety. Manual background WARNING: To prevent electric shock

use only with an extension cord suitable for outdoor use, such as SW, SOW, STW, STOW, SJW, SJOW, SJTW or SJTOW.

Extension Cord – Make sure your exten- sion cord set is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current you’re product will draw. An undersize cord will cause a drop in line voltage, re- sulting in loss of power and overheating. The table shows the correct size to use depending on cord length and name- plate ampere rating. If in doubt, use the next heavier gauge. The smaller the gauge number the heavier the cord.

MINIMUM GAUGE FOR EXTENSION CORDS (AWG)

(WHEN USING 120 V ONLY)

Amp Rating

 

Total Length of Cord in Feet (meters)

 

 

 

 

 

 

 

More Than

Not More Than

25' (7.6 m)

 

50' (15 m)

100' (30.4 m)

150' (45.7 m)

0

6

18

 

16

16

14

 

 

 

 

 

 

 

6

10

18

 

16

14

12

 

 

 

 

 

 

 

10

12

16

 

16

14

12

 

 

 

 

 

 

 

12

16

14

 

12

Not Recommended

5

Page 5
Image 5
Weed Eater 96112010100, WE18C, 438181 manual Pre-Operation, Minimum Gauge For Extension Cords Awg