GOLD CGs — User’s Information Manual

Lighting instructions

FOR YOUR SAFETY READ BEFORE OPERATING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device which auto- matically lights the burner. Do not try to light the burner by hand.

B.Before OPERATING, smell all around the ap- pliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. See below.

C.Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been under water.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

OPERATING INSTRUCTIONS

1. STOP! Read the safety information above on this label.

2. Set the thermostat to lowest setting.

3.Turn off all electrical power to the appliance.

4.Remove jacket front panel.

5. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

6. Turn Gas control knob clockwise to OFF.

7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

8. Turn Gas control knob counterclockwise to ON.

9. Turn on all electric power to the appliance.

10. Set thermostat to desired setting.

11. If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE" below and call your service technician or gas supplier.

12. Replace jacket front panel.

TO TURN OFF GAS TO THE APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed.

3.Remove jacket front panel.

4.Turn Gas control knob clockwise to OFF. Do not force.

5.Replace jacket front panel.

Part No. 550-110-261/0999

13

Page 13
Image 13
Weil-McLain GOLD CGs manual For Your Safety Read Before Operating

GOLD CGs specifications

Weil-McLain has established itself as a leader in the heating industry, and the GOLD CG series is a testament to its commitment to innovation, efficiency, and performance. The GOLD CG is a high-efficiency gas boiler designed for both residential and commercial applications. With its robust construction and intelligent engineering, it provides reliable heating while minimizing fuel consumption.

One of the standout features of the GOLD CG series is its advanced cast iron heat exchanger. This allows for excellent heat retention and optimal efficiency, ensuring that the boiler operates at a high performance level while consuming less energy. The cast iron design not only promotes longevity but also helps in maintaining consistent heating throughout the space.

Another key characteristic of the GOLD CG series is its modulating gas burner. This technology enables the boiler to adjust its output in response to the current heating demands, resulting in improved efficiency and significant energy savings. This modulation reduces short cycling, which can lead to increased wear and tear on the system over time.

The GOLD CG boilers are equipped with a user-friendly control interface, allowing homeowners and property managers to easily monitor and adjust settings. The integrated control system features advanced diagnostics that simplify troubleshooting and maintenance, making it easy to keep the system running smoothly.

Moreover, the GOLD CG series supports a wide range of installation options, including natural gas or propane configurations. This adaptability ensures that it can meet various heating needs, whether in smaller residential settings or larger commercial environments. Additionally, the compact design allows for easy placement in tight spaces, making it a versatile choice for numerous applications.

Environmental considerations are also at the forefront of the GOLD CG series. The boilers are designed to operate efficiently, which helps reduce greenhouse gas emissions. With high Annual Fuel Utilization Efficiency (AFUE) ratings, these boilers meet or exceed most energy efficiency standards, contributing to a more sustainable heating solution.

In summary, the Weil-McLain GOLD CG series stands out for its combination of efficiency, advanced technology, and thoughtful design. With features like a durable cast iron heat exchanger, modulating gas burner technology, and user-friendly controls, it provides reliable heating for a variety of applications while promoting energy conservation and sustainability. Whether for residential or commercial use, the GOLD CG series represents a top-tier choice for modern heating needs.