MOUNTING AND WIRING INSTRUCTIONS

MOUNTING AND WIRING INSTRUCTIONS

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.

1.Turn off power at circuit box to avoid possible electric shock.

2.Thread mounting screws (A) into mounting bar (B) (see fig. 1) approximately 1/4 inch.

3.Secure mounting bar (B) to outlet box (C) with outlet box screws (D) (not included).

4.To connect wires, take black fixture wire (group A from fig. 2 on page 11) and place evenly against black outlet box wire. Do not twist wires.

5.Fit wire connector (E from fig. 1) over wires and twist until there is a firm connection. If wire connector (E) easily comes off, reattach wire connector (E) and check again for a firm connection (see figure 1).

6.Repeat steps 5 and 6 with the white (group B from fig. 2) fixture wire and outlet box wires.

7.Partially thread green grounding screw (F) into side hole (G) on mounting bar (B) (see fig.1).

8.Wrap ground wire from fixture and ground wire (metal or green wire) from outlet box

(C) around green grounding screw (F) on mounting bar (B).

9.Tighten green grounding screw (F). Do not over tighten.

10.Tuckwires inside outlet box (C).

FIXTURE ASSEMBLY INSTRUCTIONS

1.Position canopy (H) over mounting screws (A) by aligning key slots (I) with mounting screws (A).

2.Rotate canopy (H) until mounting screws (A) lock into narrow end of key slots (I).

3.Install lamp(s). Do not exceed recommended wattage.

4.Unscrew thumb screws (J) enough to insert glass shade (K) (with clear glass pointed downward).

5.Carefully support glass shade (K) while securing thumb screws (J). Shade (K) is secure when thumb screws (J) fit snugly under shade lip (L).