MOUNTING AND WIRING INSTRUCTIONS

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.

1.Turn off power at circuit box to avoid possible electric shock.

2.Secure mounting bar (A) to outlet box (B) with outlet box screws (C) (not included) (see fig. 1).

3.Spread fixture arms (Y) so they are at equal distance from each other.

4.Thread hex nut 1 (D1) onto mounting nipple (E) approximately 1/4 inch and insert lock washer (F), then thread mounting nipple (E) onto mounting bar (A) and secure with hex nut 1 (D1).

5.Thread fixture loop (G) onto nipple 1 (H1) (may be preinstalled).

6.Thread hex nut 2 (D2) onto nipple 2 (H2), then thread nipple 2 (H2) into coupling (I) and secure hex nut 2 (D2).

7.Open one link on bottom end of chain (J). Attach to fixture loop (G). Securely close link on chain (J).

8.Thread screw collar ring (K) onto screw collar (L), then place canopy (M) over top of screw collar (L).

9.Lace wires up through every other link on chain (J) then through screw collar (L) and mounting nipple (E).

10.Open one link on top end of chain (J). Attach to loop on screw collar (L). Securely close link on chain (J).

11.Thread canopy (M) over top of wires and over top of screw collar (L).

12.Identify color coding of fixture wires (see fig. 2).

13.To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet box wire. Do not twist wires.

14.Fit wire connector (N from fig. 1) over wires and twist until there is a firm connection. If wire connector (N) easily comes off, reattach and check again for a firm connection.

15.Repeat steps 12 and 13 with the white (group B from fig. 2) fixture wires and outlet box wires.

16.Partially thread green grounding screw (O) into side hole (P) on mounting bar (A) (see fig. 1).

17.Wrap ground wire from fixture around green grounding screw (O) leaving enough excess wire to then connect ground wire and outlet box wire with wire connector (N), if applicable.

18.Tighten green grounding screw (O). Do not over tighten.

19.Tuck wires inside outlet box (B).

20.Remove screw collar ring (K) from screw collar (L).

21.Secure screw collar (L) to mounting nipple (E).

22.Raise canopy (M) over screw collar (L) and outlet box (B).

23.Secure canopy (M) by threading screw collar ring (K) to screw collar (L). Tighten as necessary.

FIXTURE ASSEMBLY INSTRUCTIONS

Warning: This fixture is for indoor use only.

1.Install lamp(s). Do not exceed recommended wattage.

2.Place (in order) column (Q) if applicable, column cap or nut (R), washer 1 (S1) and rubber washer (T) up to fixture ring (U), with nipple 2 (H2) protruding through opening in glass shade (V) and secure with washer 2 (S2) and hex nut 3 (D3).

3.Place decorative cap (W) over glass shade (V) and secure with finial (X).

4.Turn power back on at circuit box.

4

Page 4
Image 4
Westinghouse W-182 110712 owner manual Mounting And Wiring Instructions, Fixture Assembly Instructions