UL-ES-I56/W-WH06

Safety tips

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT",

AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES

ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.

1.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70-1996), including fire-rated construction.

2.Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

3.After making the wire connections, gently push connections into outlet box with wire nuts pointing up. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

4.Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

5.Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

6.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7.Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

8.To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support. And use mounting screws provided with the outlet box. (Mounting must support at least 35 lbs.)

9.Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.

10.Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked “Acceptable for Fan Support”.

11.To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

12.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

13.NEVER place a switch where it can be reached from a tub or shower.

14.The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

15.Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

 

TOOLS REQUIRED

 

 

Phillips Screwdriver

Wire Cutters

Pliers

Step Ladder



Page 2
Image 2
Westinghouse W-WH06 owner manual Safety tips, Observe the Following Read and Save These Instructions

W-WH06 specifications

The Westinghouse W-WH06 is an innovative water heater that stands out in the competitive market of home appliances. Designed with user convenience and efficiency in mind, this model boasts a variety of impressive features, cutting-edge technologies, and thoughtful characteristics that meet the needs of modern households.

One of the main features of the Westinghouse W-WH06 is its high-capacity design. With a 60-gallon tank, this water heater is suitable for larger families or homes with high hot water demands. The ample storage ensures that there’s enough hot water available for multiple simultaneous uses, such as showers, dishwashing, and laundry.

The water heater employs a robust heating element that enables quick recovery times, significantly reducing wait times for hot water availability. This feature is particularly beneficial during peak usage hours. The innovative design also minimizes standby heat loss, making the unit more energy-efficient compared to traditional models.

Energy efficiency is a critical characteristic of the Westinghouse W-WH06, as it is equipped with an advanced insulation system. The thick foam insulation helps maintain the temperature of the water inside the tank, resulting in lower energy costs. Furthermore, it meets or exceeds Energy Star ratings, aligning with the growing demand for sustainable and environmentally-friendly appliances.

Technological advancements in the W-WH06 include a digital temperature control system, allowing users to adjust and monitor the water temperature easily. The user-friendly interface displays current temperature readings, ensuring that it can be set to the desired level for optimal comfort and safety. Additionally, the smart diagnostics feature alerts users to any potential issues or maintenance needs, prolonging the unit's lifespan.

Durability is another hallmark of the Westinghouse W-WH06. Constructed from high-quality materials, the tank is built to resist corrosion. The inclusion of a magnesium anode rod further enhances its resilience, significantly decreasing the risk of tank deterioration over time.

Installation ease is an additional benefit of the Westinghouse W-WH06. The compact design allows it to fit in various locations within the home, making it adaptable to different space requirements. Overall, the Westinghouse W-WH06 is a reliable, energy-efficient, and user-friendly water heater, making it an excellent choice for homeowners seeking a dependable hot water solution.