Whirlpool 4454653 Befote, start, Tools needed for fnstaIIatiron, Cooktop Dimensions, Panel A

Models: 4454653

1 9
Download 9 pages 17.36 Kb
Page 2
Image 2
Befote

Befote

you

start.. .

Important:

 

 

 

 

 

 

 

Observe all governing codes and

Proper

installation

is your

responsibility.

ordinances.

Make

sure you

have

everything

for

Failure to meet governing codes and

correct

installation.

It is the responsibility

ordinances

could lead to tire or

of the

installer

to comply

with

the

electrical

shock.

installation clearances specified on the

 

 

model/serial rating

plate.

The

 

 

 

model/serial rating plate is found on the

 

 

bottom

of the

cooktop.

 

 

 

 

 

 

 

 

 

 

30” (76.2 cm) min. cabinet width

 

 

 

 

 

 

above 30” (76.2 cm) cooktop

 

 

 

 

 

 

36” (91.4 cm) mln. cabinet wldth

 

 

 

 

b-above

 

36” (91.4 cm) cooktop.

 

 

 

 

clearances,

see

 

 

 

 

 

 

 

Note:

 

 

 

 

 

min. clearance

 

 

 

 

 

upper

cabinet

 

 

 

 

 

to

countertop

 

 

 

 

 

 

 

 

I~~~kh

 

 

 

-

Do Not

seal

 

 

 

 

++cm)

 

 

 

 

 

 

 

 

cooktop

to

 

 

 

 

 

 

 

countertop.

 

 

 

 

 

 

 

 

 

 

 

 

locate

electrical

 

 

 

 

 

supply

junction

 

25”

(63.5

cm)

box

on

Boor

or

 

countertop

depth

rear

wall at

least

 

 

 

 

 

ret;29

cm)

 

 

24”

(61

cm) lower

 

 

 

 

 

cabinet

 

depth

 

 

 

 

 

 

\

 

 

 

 

 

 

 

 

Installation

above built-under

wall oven.

counte*opA

 

 

 

 

 

I I

The cutout dimensions required for the /

 

 

 

 

 

 

cooktop and the dimensions for the

 

 

 

 

 

 

 

cabinets and clearances from cabinets

 

 

 

 

 

 

 

are as shown in these Installation

 

 

 

 

 

 

 

Instructions. However see the oven

 

 

 

 

 

 

 

Installation

I structions,“Undercounter

 

 

 

 

 

 

 

installation’?

Fection,

for further

details on

*Note:

24”

(64 cm)

min. clearance

if

the proper

mounting

of the

 

bottom

of

wood

or

metal

cabinet

is

combination

of the oven and cooktop.

protected

by not

less than

1LV (0.06

cm)

 

 

 

 

flame

retardant

millboard

covered

 

 

 

 

 

wlth not less than No. 28 MSG sheet

 

 

 

 

steel, 0.015” (0.04 cm) stalnless steel,

 

 

 

 

or 0.024” (0.06 cm) aluminum or

 

 

 

 

 

0.020”

(0.05 cm)

copper.

 

 

 

 

 

 

30” (76.2 cm) min. clearance between

 

 

 

 

top of cooking platform and bottom

 

 

 

 

of an

unprotected

 

wood

or metal

 

 

 

 

 

cabinet.

 

 

 

 

 

 

30”

(76.2 cm)

wtdth

 

 

 

36”

(91.4~m)

width

 

I

 

(_

 

 

_I

Cooktop Dimensions

 

 

 

 

1” (53 cm) depth

Cooktop installed over oven installation: Only certain specified cook-top and oven models are approved for cooktop over oven installations. Cooktops approved for this type of installation will have an approval label located on the outside of the burner box. If you do not find this label, contact your dealer to confirm that cooktop is approved. The Insert Sheet included with your literature lists the cooktop and oven combinations that are approved for this type of installation.

Ovens approved for this type installation will have an approval label located on top of the oven. If you do not find this label, contact your dealer or refer to the built-under oven Installation Instructions.

30” (76.2 cm) or 36” (91.4 cm) min. base cabinet is required. If cabinet has a drawer, a 2-718”(7.3 cm) min. depth clearance from the countertop to the top of the drawer (or other obstruction) in base cabinet is required.

Check location where cooktop will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. The cooktop should be located for convenient use in the kitchen.

When installing cooktop over a built- under oven, Do Not fasten cook-top to countertop with clamps. Cooktop then will be easy to remove if servicing is ever necessary.

It is the customer’s responsibility:

To contact a qualified electrical installer.

To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 - latest edition**, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91 - latest edition”’ and all local codes and ordinances.

Injury Hazard

To eliminate the risk of burns or fire, avoid installing cabinet storage above the cooking surface. If cabinets are already installed, reduce the hazard of reaching over a heated cooking surface by installing a range hood.

The range hood should extend a minimum of 5 inches (12.7 cm) out from the bottom of the cabinets.

Reaching over a heated cooking surface could result in a serious burn.

Copies of the standards listed may be obtained from:

l * National Fire Protection Association

Batterymarch Park

Quincy Massachusetts 02269

l ** Canadian Standard Association 178 Rexdale Boulevard

Etoblcoke (foronto), Ontario M9W 1R3

2-314” (7 cm) burner box helgh

Cutout Dimensions

New installations - Follow minimum dimensions given.

Replacement

 

 

installations

- Be sure

- ‘\

that front

edge of

cooktop

is at

least

‘\

l-l /2”

(3.8 cm)

back from

‘\\,.

front

edge

of

countertop.

“x,,,

Opening Width:

30” (76.2 cm) cooktop - 29-l/T (75 cm)

36” (91.4 cm) cooktop - 35- l/2” (90.2 cm)

Tools needed for fnstaIIatiron:

Countertop

opening

-\‘\‘\

\

/

dimensions

that

are shown

\

 

 

 

must be used. Dimensions

 

7-l/2”

shown provide

minimum

 

(19

cm)

clearances,

 

 

 

 

Minimum distance to

 

 

 

 

 

nearest left side and rear

Panel A

 

 

 

 

combustible surface

 

 

 

 

above countertop

Page 2
Image 2
Whirlpool 4454653 Befote, start, Tools needed for fnstaIIatiron, Cooktop Dimensions, Cutout Dimensions, Panel A