G. Check operation

Check that you:

did not skip any steps.

installed all parts.

properly installed dryer legs.

leveled dryer.

have secured all exhaust vent joints with 4” clamps.

have all the tools you started with.

Plug power supply cord into grounded outlet. Turn power supply on.

Read the Use and Care Guide to fully understand your new dryer. Select a

full heat cycle (not the air cycle) and start dryer. After five minutes, open dryer door. You should feel heat inside dryer.

If the burner did not ignite and you do not feel heat inside the dryer, shut the dryer off for 5 minutes. Then check that:

controls are set in a running or “On” position.

start button has been pushed firmly.

gas supply line shutoff valve is open.

Repeat 5-minute test. If dryer still does not operate properly, check the following:

electrical supply is connected.

house fuse is intact and tight; or circuit breaker has not tripped.

dryer door is closed.

If dryer makes an unusual noise, check that dryer is level.

CRUSH

TM

RESISTANT

Dura Safe

 

SURE CONNECTTM Vent Kit

Kits Make Installation Easy

Periscopes For Offset

Outlets, Tight Installations

For more information, or to have your venting professionally installed, call the Consumer Assistance Center. Check your Use and Care Guide for a toll-free

Provides 4 1/2"

clearance between

dryer and wall

Snap-Lock fittings

Total kit length 8 feet

Additional vent can

be snapped between

sections for

Provides 2 1/2" clearance between dryer and wall

Great for closet installations

0"-18", 18"-29" or 29"-50" periscopes include one male snap-lock fitting, one extra

long draw-band collar and one clamp

2 1/2"

21/2"

0"-18" : Part #4396037

18"-29" : Part #4396011

29"-50" : Part #4396014

number to call or call the dealer from whom you purchased this appliance. The dealer is listed in the Yellow Pages of your phone directory under “Appliances

— Household — Major — Service and Repair.”

Part #4396028

longer runs

 

Kit Contains:

2 - 4' vent sections with attached close elbows

1 - Wall plate for close clearance installations

2 - 4" clamps

.

Dura Safe and Sure Connect are Trademarks of Whirlpool, U.S.A.

0"-18" Periscope

Use when vent outlets overlap or are offset

Excess length can

be trimmed to fitPart #4396037

18"-29" and 29"-50" Periscope

 

 

 

 

Sections separate,

Swivel collar

 

fittings can face

 

same or opposite

wall connection

 

 

Telescoping

 

Swivel collar

sections

 

 

 

 

 

 

 

Extra long

Beveled edges

 

 

band-clamp

 

 

for dryer

allow corner

 

 

connection

installations

 

 

 

 

 

 

 

 

 

 

 

18"-29" : Part #4396011

 

29"-50" : Part #4396014

11

Page 11
Image 11
Whirlpool 8535845 installation instructions Dura Safe, Check operation