S E R V I C E
Technical data
Whirlpool Europe | ADG 955 WHM | 19.03.1998 / Page 3 |
Customer Service | 8542 955 10310 | Doc. No: 4812 718 13129 |
|
|
|
Flow rates / Inlet volume |
|
|
Flow meter (at 0.3 bar |
|
|
= quantity 1.1 l/min) | 208 | lmp/l |
Spray pump | ~ 70 | l/min |
Drain pump | 16 | l/min |
Pump height max. | 1.1 | m |
Inlet valve | 4.5 | l/min |
Valve for Zone washing | 30 | l/min |
Spray arm lower | 33 | l/min |
Sprayarm upper | 27 | l/min |
Ceiling rotor | 10 | l/min |
Electrical data |
|
|
Base data |
|
|
Voltage | 220/230 | V |
Frequency | 50 | Hz |
Total power | kW | |
Fuse | 10 | A |
Motor |
|
|
Spray pump motor |
|
|
Voltage | 220/230 | V |
Power consumption | 160 | W |
HI | 81 | Ω |
HA | 44 | Ω |
Capacitor | 4 | μ F |
Drain pump motor |
|
|
Voltage | 220/240 | V |
Power consumption | 30 | W |
Resistance | 146 | Ω |
Heating |
|
|
1 Element system |
|
|
Voltage | 220/230 | V |
Power consumption | 1.87/2.04 | kW |
Resistance | 24.5 | Ω |
Heating speed | ~ 2.0 | ˚C/min |
Temperature on surface | ~ 115 | ˚C |
Safety thermostat |
|
|
self reset | 85 | ˚C |
Potentiometer |
|
|
Position 0 | 0.0 | kΩ |
Position 1 | 0.5 | kΩ |
Position 2 | 1.0 | kΩ |
Position 3 | 1.4 | kΩ |
Position 4 | 1.8 | kΩ |
Position 5 | 2.3 | kΩ |
Position 6 | 2.6 | kΩ |
Water valves |
|
|
Single valve at inlet hose |
|
|
Voltage | 220/240 | V |
Frequency | 50/60 | Hz |
Resistance | 3.76 | kΩ |
Regenerating valve |
|
|
Voltage | 220/240 | V |
Frequency | 50/60 | Hz |
Resistance | 3.13 | kΩ |
Valve for zone washing |
|
|
Voltage | V | |
Frequency | 50/60 | Hz |
Resistance | 4 | kΩ |
Coil of dispenser |
|
|
Voltage | 220/240 | V |
Frequency | 50/60 | Hz |
Resistance | 1.5 | kΩ |
Reedcontact |
|
|
flow meter |
|
|
salt control |
|
|
NTC |
|
|
15 ˚C | 75 | kΩ |
20 ˚C | 62 | kΩ |
30 ˚C | 43 | kΩ |
40 ˚C | 28 | kΩ |
50 ˚C | 19 | kΩ |
60 ˚C | 13 | kΩ |
70 ˚C | 9 | kΩ |
80 ˚C | 6 | kΩ |
85 ˚C | 5 | kΩ |