![](/images/new-backgrounds/1085229/852295x1.webp)
S E R V I C E
Technical data
Whirlpool Europe | ADP 905/3 WH | 12.07.1999 / Page 3 |
Customer Service | 8542 905 01410 | Doc. No: 4812 718 14342 |
|
|
|
Drain pump motor |
|
|
Voltage | 220/240 | V |
Power consumption | 30 | W |
Resistance | 146 | Ω |
Heating |
|
|
1 Element system |
|
|
Voltage | 220/230 | V |
Power consumption | 1.87/2.04 | kW |
Resistance | 24.5 | Ω |
Heating speed | ~ 2.0 | ˚C/min |
Temperature on surface | ~ 115 | ˚C |
Safety thermostat |
|
|
self reset | 85 | ˚C |
Water valves |
|
|
Single valve at inlet hose |
|
|
Voltage | 220/240 | V |
Frequency | 50/60 | Hz |
Resistance | 3.76 | kΩ |
Regenerating valve |
|
|
Voltage | 220/240 | V |
Frequency | 50/60 | Hz |
Resistance | 3.13 | kΩ |
Coil of dispenser |
|
|
Voltage | 220/240 | V |
Frequency | 50/60 | Hz |
Resistance | 1.5 | kΩ |
Reedcontact |
|
|
flow meter |
|
|
NTC |
|
|
15 ˚C | 75 | kΩ |
20 ˚C | 62 | kΩ |
30 ˚C | 43 | kΩ |
40 ˚C | 28 | kΩ |
50 ˚C | 19 | kΩ |
60 ˚C | 13 | kΩ |
70 ˚C | 9 | kΩ |
80 ˚C | 6 | kΩ |
85 ˚C | 5 | kΩ |
Regeneration |
|
|
Volume | 300 | cm3 |
Position 0 |
|
|
after wash cycles | 10 |
|
water hardness | ˚dh | |
| mmol/l | |
| ˚Fh | |
Salt consumption for |
|
|
regeneration | 77 | g |
Number of cycles |
|
|
with 2 kg salt | 26 |
|