Whirlpool AKM 250 WH service manual S E R V I C E, Technical data

Models: AKM 250 WH WH 250 AKM

1 5
Download 5 pages 46.37 Kb
Page 2
Image 2
S E R V I C E

12.08.1997 / Page 2

AKM 250/WH

Whirlpool Europe

 

S E R V I C E

Doc. No: 4812 715 16755

8571 250 35010

Customer Service

 

 

 

 

 

Technical data

1. Medium Burner

2. Medium Burner

3. Large Burner

4. Small Burner

Voltage: 230 V

Frequency: 50 Hz

Type of gas used

 

Type of

 

Injector

Rated heat

Rated

 

 

Reducedheat

Gas pressure (mbar)

 

 

burner

 

marking

 

capacity

consumption

 

capacity

 

 

 

 

 

 

 

 

 

 

PCS-kW

 

 

 

 

PCS-kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

min.

rat.

max.

Natural Gas

 

large

 

128

3,00

286 l/h

 

 

0,60

 

 

 

(Methane)

 

medium

 

94

1,65

157 l/h

 

 

0,35

17

20

25

G 20

 

small

 

79

1,00

95 l/h

 

 

0,30

 

 

 

Natural Gas

 

large

 

85

3,00

218 g/h

 

 

0,60

 

 

 

(Cylinder)

 

medium

 

65

1,65

120 g/h

 

 

0,25

20

28-30

35

G 30

 

small

 

50

1,00

73 g/h

 

 

0,30

 

 

 

Natural Gas

 

large

 

85

3,00

214 g/h

 

 

0,60

 

 

 

(Cylinder)

 

medium

 

65

1,65

118 g/h

 

 

0,25

25

37

45

G 31

 

small

 

50

1,00

71 g/h

 

 

0,30

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas used

 

Appliance

 

Total rated heat

 

 

Total rated

Air required for

 

 

 

 

model

 

capacity

 

consumption

burning m3 /h

 

 

 

 

 

 

 

PCS-kW

 

 

 

 

 

 

 

G20 20 mbar

 

 

 

4G

 

7,30

 

 

 

 

695 l/h

 

14,6

 

G30 28-30 mbar

 

 

 

4G

 

7,30

 

 

 

 

531 g/h

 

14,6

 

G31 37 mbar

 

 

 

4G

 

7,30

 

 

 

 

521 g/h

 

14,6

 

Page 2
Image 2
Whirlpool AKM 250 WH service manual S E R V I C E, Technical data