Whirlpool GH5176XP dimensions Microwave Hood Combination, Product Model Numbers, Abc Defg

Models: GH6177XP GH5184XP GH5176XP GH6178XP

1 1
Download 1 pages 54.77 Kb
Page 1
Image 1
Microwave Hood Combination

®

Microwave Hood Combination

PRODUCT MODEL NUMBERS

GH5176XPGH6177XP

GH5184XPGH6178XP

Electrical: A 120 Volt, 60 Hz, AC only, 15- or

20-amp fused electrical supply (or circuit breaker) is required. (A time-delay fuse or circuit breaker is recommended.) It is recommended that a separate circuit serving only this appliance be provided.

OVERALL DIMENSIONS

17¹⁄₈"

 

 

 

 

 

15⁷⁄₈"

 

 

 

 

 

(40.3 cm)

(43.5 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

)

 

 

 

 

 

 

5.9 cm

 

 

 

 

 

" (7

 

 

 

 

⁷⁄₈

 

 

1

29

 

 

 

 

 

 

(

 

 

⁄₈

 

 

 

39.

 

"

 

 

 

 

1

c

 

 

 

 

 

 

m)

 

 

 

VENTING REQUIREMENTS

A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used.

The total length of the vent system including straight vent, elbow(s), transitions and wall or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent.

For best performance, use no more than three 90° elbows.

To calculate the length of the system you need, add the equivalent length for each vent piece used in the system. See the following examples:

ABC

DEFG

A. Rectangular to round transition piece: 3¹⁄₄" x 10" to 6" = 5 ft (8.3 x 25.4 cm to 15.2 cm = 1.5 m)

B. Roof cap: 3¹⁄₄" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m)

C. 90° elbow: 3 " x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m)

D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m)

E. Wall cap: 3¹⁄₄" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m)

F. 45° elbow: 6" = 5 ft (15.2 cm = 1.5 m)

G. 90° flat elbow: 3¹⁄₄" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)

6" (15.2 cm) vent system = 73 ft (22.2 m) total

AB

6 ft (1.8 m)

2ft

(0.6 m)

CD

A. Two 90° elbows = 20 ft (6.1 m)

B. 1 wall cap = 40 ft (12.2 m)

C. 1 rectangular to round transition piece = 5 ft (1.5 m)

D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

CABINET OPENING DIMENSIONS

A

B

30"

 

(76.2 cm)

 

min.

 

 

12" (30.5 cm) min.

 

14" (35.6 cm) max.

66" (167.6 cm) min.

 

A. 2" x 4" wall stud

 

B. Grounded 3 prong outlet

3¹⁄₄" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total

AB

6 ft (1.8 m)

2ft

(0.6 m)

C

A. One 3¹⁄₄" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)

B. 1 wall cap = 40 ft (12.2 m)

C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. 8205139

Instructions packed with product. Specifications subject to change without notice.

08-23-05

Page 1
Image 1
Whirlpool dimensions Microwave Hood Combination, Product Model Numbers, GH5176XPGH6177XP GH5184XPGH6178XP, Abc Defg