® Ice Maker
PRODUCT MODEL NUMBERS
GI15NDXT GI15NFRT
GI15NFLT
Electrical: A 115 Volt, 60 Hz., AC only, 15- or
It is recommended that a separate circuit, serving only your ice maker, be provided. Use a receptacle which cannot be turned off by a switch or pull chain.
Water: A cold water supply with water pressure of between 30 and 120 psi (207 and 827 kPa) is required to operate the ice maker.
IMPORTANT: Reverse osmosis water filtration systems can be used only with ice maker installations that have a gravity drain. A reverse osmosis system is not recommended for ice makers that have a drain pump installed.
The pressure of the water supply coming out of a reverse osmosis system going to the water inlet valve of the ice maker needs to be between 30 and 120 psi (207 and 827 kPa).
Drain: Either a
DRAIN REQUIREMENTS
CABINET OPENING DIMENSIONS
|
| 11¹⁄₂ " | A |
|
| (29.2 cm) | |
34" |
|
|
|
(86.4 cm) |
|
|
|
Min. |
|
| 28¹⁄₂ " |
34¹⁄₂ " |
|
| |
(87.6 cm) |
|
| (72.4 cm) |
Max. | 3¹⁄₂ " | 9" |
|
| (8.9 cm) (22.9 cm) |
| |
| 24" |
| B |
|
|
| |
| (60.1 cm) |
| |
|
| 15" |
|
| (38.1 cm) |
|
A. Recommended location for electrical and plumbing fixtures.
B. Floor level
REAR VIEW
A
B
C
D
E
A. Water supply tube clamp
B. Vent hose (drain pump models only) C. Water supply line
D. Inlet water tube clamp
E. Drain hose (drain pump models only)
SIDE VIEW
A
B
1⁷⁄₈"
(4.8 cm)
1" (2.54 cm)
23" |
| C |
(58.4 cm)
D
2" - 1¹⁄₂"
(5 cm - 3.8 cm)
A. Drain hose
B. 1" (2.54 cm) air gap C. PVC drain reducer
D. Center of drain should be 23" (58.4 cm) from front of door, with or without the ³⁄₄" (1.91 cm) panel on the door. The drain should also be centered from left to right (7⁵⁄₁₆" [18.57 cm] from either side of the ice maker).
■Drain lines must have a minimum of 5⁄8"
(15.88 mm) inside diameter.
■Drain lines must have a 1" drop per 48"
(2.54 cm drop per 122 cm) of run or 1⁄4" drop per 12" (6.35 mm per 30.48 cm) of run and must not have low points where water can settle.
■The floor drains must be large enough to accommodate drainage from all drains.
■The ideal installation has a standpipe with a
1" (2.54 cm) air gap between the drain hose and the standpipe.
■It may be desirable to insulate the drain line thoroughly up to the drain inlet.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10136155B |
Instructions packed with product. Specifications subject to change without notice. | |
|