Gas Built-in Cooktop
PRODUCT MODEL NUMBERS
GLS3665R
This cooktop is
LP Gas conversion:
Conversion must be done by a qualified service technician.
Gas Supply Line:
•Provide a gas supply line of 3⁄4" (1.9 cm) rigid pipe to the cooktop location. A smaller size pipe on longer runs may result in insufficient gas supply.
Flexible metal appliance connector:
•If local codes permit, use a 5⁄8" flexible stainless steel tubing gas connector, designed by CSA to connect the cooktop to the rigid gas supply line.
•A 1⁄2" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator.
•Do not kink or damage the flexible metal tubing when moving the cooktop.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings to obtain an
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the cooktop opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the cooktop.
B
A
C
A. Gas supply line
B. Shutoff valve “open” position
C. To cooktop
Electrical: A 120 volt, 60 Hz., AC only,
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
INSTALLATION CLEARANCES
|
| D |
| B |
|
| C |
|
|
| F |
|
| J |
A | I | E |
|
|
G
H
A. 18" (45.7 cm) minimum clearance upper cabinet to countertop
B.Cabinet
C.36" (91.4 cm) on 36" (91.4 cm) models
D.13" (33 cm) maximum recommended upper cabinet depth
E.6" (15.2 cm) minimum side wall clearance
F.30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet (24" [61 cm] minimum clearance if bottom of wood or metal cabinet is protected by not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
G.2⁵⁄₁₆" (5.9 cm) minimum distance to rear combustible surface
H.3³⁄₁₆" (8.1 cm) minimum distance to front countertop edge
I.Cutout width - 35³⁄₈" (89.9 cm)
J.Cutout depth - 19¹⁄₂" (49.5 cm)
OVERALL DIMENSIONS
A
C |
| A. 36" (91.4 cm) |
| B | B. 20¹⁄₈" (51.1 cm) |
| C. 2²⁷⁄₃₂" (7.2 cm) | |
|
|
GAS AND ELECTRIC CONNECTION LOCATIONS
| A |
C | B |
| C |
| L |
| D |
A. Gas pressure regulator (supplied) - arrow pointed toward cooktop B. 3 prong grounding type outlet with correct polarity
C. 18" (45.7 cm) minimum D. Gas shutoff valve
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10526418A |
Instructions packed with product. Specifications subject to change without notice. | 9/17/13 |