Whirlpool ADG 955 NBM S E R V I C E, Technical data, Flow rates / Inlet volume

Models: ADG 955 NBM 955 NBM

1 17
Download 17 pages 5.5 Kb
Page 3
Image 3
Flow rates / Inlet volume

S E R V I C E

Technical data

Whirlpool Europe

ADG 955 NBM

12.07.1999 / Page 3

Customer Service

8542 955 10420

Doc. No: 4812 718 14583

 

 

 

Flow rates / Inlet volume

 

 

Flow meter (at 0.3 bar

 

 

= quantity 1.1 l/min)

208

lmp/l

Spray pump

~ 70

l/min

Drain pump

16

l/min

Pump height max.

1.1

m

Inlet valve

4.5

l/min

Valve for Zone washing

30

l/min

Spray arm lower

33

l/min

Sprayarm upper

27

l/min

Ceiling rotor

10

l/min

Electrical data

 

 

Base data

 

 

Voltage

220/230

V

Frequency

50

Hz

Total power

2.0-2.2

kW

Fuse

10

A

Motor

 

 

Spray pump motor

 

 

Voltage

230/240

V

Power consumption

160

W

HI

81

Ω

HA

44

Ω

Capacitor

4

μ F

Drain pump motor

 

 

Voltage

220/240

V

Power consumption

30

W

Resistance

146

Ω

Heating

 

 

1 Element system

 

 

Voltage

220/230

V

Power consumption

1.87/2.04

kW

Resistance

24.5

Ω

Heating speed

~ 2.0

˚C/min

Temperature on surface

~ 115

˚C

Safety thermostat

 

 

self reset

85

˚C

Potentiometer

Points of measurement: 1 (black) to 2 (middle)

Position 0

0.0

kΩ

Position 1

0.5

kΩ

Position 2

1.0

kΩ

Position 3

1.4

kΩ

Position 4

1.8

kΩ

Position 5

2.3

kΩ

Position 6

2.6

kΩ

Water valves

 

 

Inlet valve

 

 

Voltage

220/240

V

Frequency

50/60

Hz

Resistance

3.76

kΩ

Regenerating valve

 

 

Voltage

220/240

V

Frequency

50/60

Hz

Resistance

3.13

kΩ

Valve for zone washing

 

 

Voltage

220-240

V

Frequency

50/60

Hz

Resistance

4

kΩ

Coil of dispenser

 

 

Voltage

220/240

V

Frequency

50/60

Hz

Resistance

1.5

kΩ

Reedcontact

flow meter salt control

Page 3
Image 3