RGH 8300-l '%
..RGHt!S3m-25
TO INSTALL RANGE HOOD
This unit can be vented vertically through uoper cabine!s or horrzontally through an outside wall. A typical vertical installet~on iS shown in Figure 1. A ryolcal horizonial rnstallatron IS shown In Figure
2. For proper ventila:ron when used wrth an indoor electrrc grill. see paoe 2 for gurctelines for proper auct sizing. Improper duct sizing or ins:alletion of restrictive roof jacks can reduce air moving capacity and provide inadequate ventilation for an indoor electric grill. For mcst efficient smoke removal, the top of the hood should be
approximately 56 Inches (13T.6 cm) from the floor.
1. Make a template or transfer measurements shown in Fig. 3 to cabinets or wall.
2. Cut holes to accomodate ventilating duct allowing ‘4”
vent.
FIGURE 2
3. Cut appropriate hole for electrical wiring.
4.Run wire through wall or cabinets according to Nattonal Electrical Code and applrcable local codes. (DO NOT turn power on until installation is complete.)
5, For an easrer rnstallaiion. remove the filters and the three assembltes shown in Frg. 4. Thus reduces the weight about 40%. The blower cover and light frame assembly are held into place with thumb screws. To romove the blower assembly, first unplug the blower power supply cord f:om the junction box. Remove the packing screw from the b!ower retarnrno rod. then pull the blower retalntng rod to one side. freeing it from between the bumps on the blower housing.
6. | Remove | screw | holding | junction box | cover. | . | |
7. | Remove | proper | electrical | knockout, | See Figure 3. | ||
|
8. | Remove | proper | venting | knockout. | See | Figure 3. NOTE: | If | |||||
horizonta! discharge is selected an additronal knockout in the blower | ||||||||||||
cradle | must | be removed. |
|
|
|
|
|
|
| |||
9. Attach !he damoer as shown in Figure 5 for vertical discharge or | ||||||||||||
Fig. 6 for horizontal | discharge. |
|
|
|
|
|
|
| ||||
10. | Lift | the | hood | into | position. | Mark | location of | four | mounting | holes. | ||
11. | Remove | hood | and start all | four | screws | in center | of narrow | neck | of |
.
FIGURE 3
L
keyhole slot marked on cabmet bottom. |
|
|
|
|
| |||||||||
72. | Lift | the | hood | into | posrrion | simultaneously |
| feeding | the electrical | |||||
wire |
| through | the | knockout. | Fojlow aoplicable | local codes | and/or | |||||||
latest | Nattonal | Electrrcal | Code for | electrical | connector | to be | used at | |||||||
field | wiring | entrance. |
|
|
|
|
|
|
|
| ||||
13. | Tighten | screws | to | secure | hood. | Be | sure | screw head | is in narrow | |||||
neck | of | keyhole | slot. |
|
|
|
|
|
|
|
| |||
14. | Install proper | duct | work. | See | page | 2. |
|
|
|
|
16.COmplete electrical wiring
16.Replace junction box cover,
17.Replace blower. See page 3 for proper blower orientation
18.Replace blower cover. light frame assembly and filters.
NOTE: It has been found that a large part of the energy loss of the average home IS due to outslde air InfIltratIng the structure, Sea) around duc!work wncre It passes through outside walls or ceilrng.
L4
\
i
- J’JYCTION 90x
.
COVER-BLOWER CRADLE .