INSTALLATION and OPERATING INSTRUCTIONS
for
~irlpool | VENTED | RANGE | HOOD | RHH 2300SERlES |
TO INSTALL
For most efficient operation, the top of the hood should be
approximately 66 inches (137.6 cm) from the floor. See Figure 5 for examples of two typical ductwork
installations. Choose the best method for your installation.
1. Mark |
| locations | for | ventilating | duct | and | electrical | |||||||||
| wiring | from | dimensions | given in figure | 1. |
|
|
| ||||||||
2. | Cut |
| holes | at | marked | locations | to | accomodate | ||||||||
| ventilating | duct | and | electrical | wiring. | Allow | %” | (1.91 | ||||||||
| cm) extra on ventilating opening toward the front of | |||||||||||||||
| the cabinet directly above the hood (See Figure 4). | |||||||||||||||
| Be sure to minimize openings through the outside | |||||||||||||||
| walls or ceiling. These will have to be sealed later. | |||||||||||||||
3. Run the wire through the wall or cabinets according | ||||||||||||||||
| to the National Electrical Code and applicable local | |||||||||||||||
| codes. | DO NOT | turn | power | on | until | installation | is | ||||||||
| complete. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
4. | Remove | the | screws |
| holding | the | junction | box | cover | |||||||
| (See |
| Figure | 3). |
|
|
|
|
|
|
|
|
|
|
| |
5. | Lift | the | hood | into | position | and | mark | the |
| hole | ||||||
| locations on the cabinet for each of the four keyhole | |||||||||||||||
| mounting | slots. |
|
|
|
|
|
|
|
|
|
|
| |||
6. | Remove | the hood and start all four screws | in | the | ||||||||||||
| center | of the | narrow |
| neck | of the | keyholeslot | marked | ||||||||
| on the cabinet bottom (See Figure 2). |
|
|
|
| |||||||||||
7. | Install | proper | ductwork. |
|
|
|
|
|
|
|
| |||||
8. | Lift | the | hood into | position | simultaneously | feeding |
RANGE HOOD
KEYHOLE SLOTS
L WIRING KNOCKOUT
FIG. 1
KEYHOLE SLOT
IN CANOPY
IIN INSTALLATION | LJUNCTION | BOX | |
PARTS | BAG1 |
the electrical | wire through the knockout. |
COVER
9. Tighten the four mounting screws to secure theFIG. 2 hood to the cabinet. Be sure the screw heads are in
the narrow neck of the keyhole slot (Figure 2).
10. Complete electrical wiring in the juction box according to the National Electrical Code and applicable local codes,
11.Replace junction box cover.
12.Seal holes around ventilating pipe and wiring passing through ceiling oroutsidewall with caulking or insulation to prevent energy loss.
NOTE: It has been found that a large part of the energy loss of the average home is due to outside air infiltrating the structure. Seal around duct work where it passes through outside walls or ceiling. Seal around electrical wiring and be sure the damper is working properly.
FIG. 3
STARTER HOLES