30" (76.2 CM) Freestanding Gas Range | |
PRODUCT MODEL NUMBERS | Electrical Requirements: |
SF216LXS | ● A 120 volt, 60 Hz., AC only, |
Gas Supply Requirements: | |
that a separate circuit serving only this range be provided. | |
Type of Gas | ● This range is equipped with a power supply cord having a 3 prong ground |
Natural gas: | plug. To minimize possible shock hazard the cord must be plugged into a |
grounded 3 prong outlet. | |
This range is | ● Electronic ignition systems operate within wide voltage limits, but proper |
gas or, after proper conversion, for use with LP gas. | grounding and polarity are necessary. Check that the outlet provides |
● This range is factory set for use with Natural gas. See “Gas | power and is correctly grounded. |
This range is equipped with an electronic ignition system that will not operate | |
Conversions” section. The model/serial rating plate located on the | if plugged into an outlet that is not properly polarized. |
oven frame behind the left side of the broiler door has information on |
|
the types of gas that can be used. If the types of gas listed do not | PRODUCT DIMENSIONS |
include the type of gas available, check with the local gas supplier. | |
LP gas conversion: |
|
Conversion must be done by a qualified service technician. |
|
No attempt shall be made to convert the appliance from the gas |
|
specified on the model/serial rating plate for use with a different gas |
|
without consulting the serving gas supplier. See “Gas Conversions” |
|
section. |
|
Gas Supply Line |
|
●Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range
location. A smaller size pipe on longer runs may result in insufficient | A |
gas supply. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) | |
minimum. Usually, LP gas suppliers determine the size and materials |
|
used in the system. |
|
NOTE: | B |
be used. Do not use TEFLON®† tape. |
Flexible metal appliance connector:
●If local codes permit, a new CSA
appliance connector may be used for connecting range to the gas |
|
|
| C | ||||||||||||
supply line. |
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
● A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the | E |
| ||||||||||||||
female pipe threads of the inlet to the appliance pressure regulator. |
|
|
|
| ||||||||||||
|
|
|
| |||||||||||||
● Do not kink or damage the flexible metal tubing when moving the |
|
|
|
| ||||||||||||
range. |
|
| D |
| ||||||||||||
Rigid pipe connection: |
|
|
|
| ||||||||||||
|
|
|
| |||||||||||||
The rigid pipe connection requires a combination of pipe fittings to |
|
|
|
| ||||||||||||
obtain an |
| A. 26¼" (67.9 cm) with handle | ||||||||||||||
with the range connection. All strains must be removed from the |
| B. 36" (91.4 cm) | ||||||||||||||
supply and fuel lines so range will be level and in line. |
| C. 46¼" (117.5 cm) | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| D. 29⁷⁄₈" (75.9 cm) | ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| E. 24¼" (61.6 cm) | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
●Must include a shutoff valve:
The supply line must be equipped with a manual shutof valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.
| B |
|
A | A. Gas supply line |
|
B. Shutoff valve “open” position |
| |
|
| |
| C. To range |
|
| C |
|
†®TEFLON is a registered trademark of E.I. Du Pont Nemours and Company. | Page 1 of 2 | |
|
|
Because Whirlpool Corporation policy includes a continuous commitment to improve | Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10477536B |
our products, we reserve the right to change materials and specifications without notice. | Instructions packed with product. Specifications subject to change without notice. | 3/19/13 |