Curved-edge glass cooktops
B
A
C
A. 21¹⁄₈" (53.7 cm)
B. 30⁵⁄₁₆" (77.0 cm) on 30" (76.2 cm) models, 36⁵⁄₁₆" (92.3 cm) on 36" (91.4 cm) models
C. 2⁷⁄₈" (7.3 cm)
Cabinet Dimensions
IMPORTANT: If installing a range hood or microwave hood combination above the cooktop, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
A
D
CB
NOTES: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the countertop to the top of the drawer (or other obstruction) in base cabinet is required. The drawer depth may need to be shortened to avoid interfering with the regulator.
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
M
K E
FG
H
IMPORTANT: The cooktop must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system that
LJ
JI
A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of unprotected wood or metal cabinet (24" [61 cm] minimum clearance if bottom of wood or metal cabinet is protected by not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, or
0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper) D. 13" (33 cm) recommended upper cabinet depth
E.2¹⁄₈" (5.4 cm)
F.19" (48.3 cm)
G.18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop
H.Grounded outlet - Locate within 24" (61 cm) of right rear corner of cutout
I.29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models
J.8³⁄₈" (21.3 cm) minimum distance to nearest left and right side combustible surface
K.2⁷⁄₈" (7.3 cm) minimum distance to rear combustible surface
L.Gas line opening - Wall: anywhere 5" (12.7 cm) below
underside of countertop. Cabinet floor: Anywhere within 6" (15.2 cm) of rear wall is recommended
M.24" (61 cm) minimum countertop depth is required
will not operate if plugged into an outlet that is not properly polarized.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio
■A 120 volt, 60 Hz, AC only,
■Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. Check that the outlet provides
■The wiring diagrams are provided with this cooktop. See “Wiring Diagrams” section.
4