2.Remove neutral ground wire from internal ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center silver- colored terminal block screw. Tighten screw.
A
| B |
E D | C |
A. Center
B. Neutral ground wire - Dotted line shows position of NEUTRAL ground wire before being moved to center
C. Internal ground conductor screw D. Neutral wire (white or center wire) E. ¾" (19 mm) UL listed strain relief
3.Move the green painted screw from the internal to the external ground conductor location. Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.
B
A C
G F E D
A. Neutral wire (white or center wire)
B. Center
C. Neutral ground wire
D. External ground conductor screw
E. Ground wire (green or bare) of power supply cord
F. Internal ground conductor location
G. ¾" (19 mm) UL listed strain relief
4.Connect the other wires to outer terminal block screws. Tighten screws.
5.Tighten strain relief screws.
6.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
7.You have completed your electrical connection. Now go to “Venting Requirements.”
4-wire connection: Direct Wire
IMPORTANT: A
Direct wire cable must have 5 ft (1.52 m) of extra length so washer/dryer can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 11⁄2" (38 mm) from
3 remaining wires. Strip insulation back 1" (25 mm). Shape ends of wires into a hook shape.
1" (25mm)
(127 | 5" | |
mm) | ||
|
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together, and tighten screw. See example below.
1.Remove center
2.Remove neutral ground wire from internal ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.
| A |
| B |
E D | C |
A. Center
C. Internal ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center
D. Neutral wire (white or center wire) E. ¾" (19 mm) UL listed strain relief
7