Gas Dryer
PRODUCT MODEL NUMBERS
WGD9200S WGD9400S WGD9500T
WGD9300V WGD9400V WGD9600T
RECOMMENDED INSTALLATION SPACING FOR RECESSED OR CLOSET INSTALLATION, WITH STACKED WASHER AND DRYER
Dimensions shown are for recommended spacing.
48 in.2 *
(310 cm2)
6"* (152 mm)
3"* (76 mm)
| 3"* (76 mm) |
|
24 in.2 * | 1"* (25 mm) | A* |
(155 cm2) |
|
|
* Required spacing
76" (1930 mm)
1" (25 mm)
| Steam | |
| (Electric or Gas) | (Electric or Gas) |
|
|
|
A* | 5 ½" (140 mm) | 5" (127 mm) |
|
|
|
*Required spacing
NOTE: Some models are not recommended for stacked recessed or closet installation.
| 27" |
|
|
| 1" |
(686 mm) | (25 mm) |
CUSTOM UNDERCOUNTER INSTALLATION – DRYER ONLY
Dimensions shown are for minimum spacing.
A
B
C* D E*
*Required spacing
EXHAUST VENTING
| Steam | |
| (Electric or Gas) | (Electric or Gas) |
|
|
|
A | 0" (0 mm) | 0" (0 mm) |
|
|
|
B | 38" (9652 mm) | 38" (9652 mm) |
|
|
|
C* | 1" (25 mm) | 1" (25 mm) |
|
|
|
D | 27" (686 mm) | 27" (686 mm) |
|
|
|
E* | 1" (25 mm) | 1" (25 mm) |
|
|
|
*Required spacing
NOTE: Some models are not recommended for undercounter installation.
A and B: Recommended hood styles.
C:Acceptable hood style.
B
A | 4" |
(102 mm) |
| 4" |
(102 mm) | |
4" | A. Louvered hood style |
(102 mm) |
B. Box hood style
C. Angled hood style
C
2½" (64 mm)
NOTE: Side and bottom exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.
Number | Type of vent | Box /louvered | Angled |
90º elbows |
| hoods | hoods |
|
|
|
|
0 | Rigid metal | 64 ft (20 m) | 58 ft (17.7 m) |
|
|
|
|
1 | Rigid metal | 54 ft (16.5 m) | 48 ft (14.6 m) |
|
|
|
|
2 | Rigid metal | 44 ft (13.4 m) | 38 ft (11.6 m) |
|
|
|
|
3 | Rigid metal | 35 ft (10.7 m) | 29 ft (8.8 m) |
|
|
|
|
4 | Rigid metal | 27 ft (8.2 m) | 21 ft (6.4 m) |
|
|
|
|
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible.
Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need.
Page 3 of 3
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10224610 |
Instructions packed with product. Specifications subject to change without notice. |