TROUBLESHOOTING27
PROBLEM: TV Interference
Problem Solution
Electrical interference from Add a Ferrite data line
filter inverter. on to the TV power cord.
This filter is available at
RadioShack, or other
electronic supply stores.
part number 273-105.
PROBLEM: Low or No Output Voltage
Problem Solution
Using incorrect type of Use true RMS reading meter
voltmeter to test output See "For You Technical
voltage. Types"
Section of this manual.
PROBLEM: Low Battery Alarm On All The Time
Problem Solution
Input voltage below Keep input voltage above
11 volts. 11 volts to maintain
regulation.
Poor or weak battery Replace battery.
condition.
Inadequate power being Use lower gauge wire. See
delivered to the inverter “W ire Cable Gauges”
or excessive voltage drop. section of this manual.
Keep wire length as short
as possible.
OPERATION SUMMARY
Always operate the inverter in accordance with the
instructions in this manual. Failure to do so may result
in property dam age, personal injury, or loss of life.
While connecting the inverter to the power source,
make certain that the inverter is well removed from
any potential source of flammable fumes or gases.
Always ground the inverter before operating it.
In the event a continuous audible alarm or automatic
shut off, turn the inverter OFF immediately. Do not
restart the inverter until the source of the problem has
been identified and corrected.