pro800w.qxp 4/30/2010 9:00 AM Page 7

WHISTLER FEATURES

1.Two 110 AC Outlets

2.On/Off Switch

Turns the unit On/Off.

3.On/Shutdown Indicator Light

The LED will illuminate GREEN when the inverter is powered in normal conditions. This light will turn RED and the inverter will automatically shut down (except low voltage alarm) when any of the following problems occur:

Short Circuit Protection. The inverter will shut down until the short is removed.

Low Voltage Alarm. An alarm will sound when the voltage from the battery discharges to 10.5+/-0.5 volts DC. This is an indication that the battery needs to be recharged.

Over Voltage Protection. The inverter will turn itself off when the input exceeds 15.5+/-0.5 volts DC.

Under Voltage Protection. The inverter will turn itself off when the input is less than 10.0+/-0.5 volts DC.

Overload Protection. The inverter will turn itself off when the continuous draw or the surge draw of the equipment being operated exceeds the maximum power rating for the inverter.

Thermal Protection. The inverter will turn itself off when the internal temperature exceeds safe design parameters.

WHISTLER FEATURES

4.USB Power Port

5.Cooling Fan

6.Power Input Terminal (Negative)

(Observe proper polarity)

7.Power Input Terminal (Positive)

(Observe proper polarity)

Note:

In the event of an automatic shut down or continuous audible alarm, turn the inverter OFF (O) until the source of the related problem has been determined and resolved.

4

5

Page 4
Image 4
Whistler PRO-800W owner manual USB Power Port Cooling Fan Power Input Terminal Negative