White Rodgers 1.00E+78 installation instructions Your Thermostat Replaces, Contents, Preparations

Models: 1.00E+78

1 8
Download 8 pages 5.42 Kb
Page 1
Image 1
Installation Instructions for

Installation Instructions for

Heating & Air Conditioning

1E78

5/2 Day Programmable Thermostat

YOUR THERMOSTAT REPLACES

Typical System Compatibility Chart

1E78

 

 

 

 

Standard Heat Only Two Wire Gas or Oil Fired Systems (24 volt)

Yes

 

Electronic Ignition Heat Only Two Wire Systems (24 volt)

Yes

 

 

 

 

Electronic Ignition Heat Only Gas or Oil Fired Systems (24 volt)

Yes

 

Standard Heat/Cool Systems (24 volt)

Yes

 

 

 

 

Heat/Cool Systems Electric Heat (24 volt)

Yes

 

Heat Only Electric Heat Systems (24 volt)

Yes

 

Cool Only Systems (24 volt)

Yes

 

 

 

 

Heat Pump Systems (No Aux or Emergency Heat)

Yes

 

 

 

 

Hot Water Zone Heat Only (Two Wire) Systems

Yes

 

Hot Water Zone Heat Only (Three Wire) Systems

No

 

Line Voltage Heating or Baseboard 110/240 Volt Systems

No

 

Millivolt Systems Floor or Wall Furnaces

Yes

 

12 VDC Mobile Home Application

Yes

 

 

 

 

Multistage Systems

No

 

 

 

 

Systems Exceding 30VAC, 1.5 Amp

No

 

 

 

 

 

 

 

CONTENTS

 

Preparations

1

Thermostat Details

1

Removing Old Thermostat

1

Mounting and Wiring

2

Check Thermostat Operation

3

Programming your Thermostat

4

Specifications

6

Troubleshooting

6

1 PREPARATIONS

Assemble tools required as shown below.

FLAT BLADE SCREWDRIVER

HAND OR POWER

DRILL WITH 3/16 INCH

DRILL BIT, IF NEEDED

WIRE CUTTER/STRIPPER

Failure to follow and read all instructions carefully before installing or operating this control could cause personal injury and/or property damage

2 THERMOSTAT DETAILS

Mounting

Hole

 

 

 

W905

 

 

 

W904

RC

G

RH W

W903

Y

O

B

 

 

 

 

ELEC

GAS

 

 

 

 

Elec/Gas

Base

Mounting

Back of

Switch

Hole

Thermostat Body

 

 

W903

- clip to disable EMR feature

 

W904

- clip for Celcius display

 

W905

- clip for hydronic system

Figure 1. Thermostat

3 REMOVING OLD THERMOSTAT

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electrical power to the system at the main fuse or circuit breaker until installation is complete.

Before removing wires from old thermostat’s switching subbase, label each wire with the terminal designation it was removed from.

1.Remove Old Thermostat: A standard heat/cool thermostat consists of three basic parts:

a.The cover, which may be either a snap-on or hinge type.

b.The base, which is removed by loosening all captive screws.

c.The switching subbase, which is removed by unscrewing the mounting screws that hold it on the wall or adaptor plate.

2.Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected.

3.Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly.

4.Identify each wire attached to the old thermostat.

5.Disconnect the wires from the old thermostat one at a time. DO

NOT LET WIRES FALL BACK INTO THE WALL.

6.Install new thermostat using the following procedures.

White-Rodgers is a division

PART NO. 37-6542B

of Emerson Electric Co.

Replaces 37-6542A

www.white-rodgers.com