Type 179

Type 179

WHITE-RODGERS

SPDT Heating/Cooling Room Thermostat

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

These room thermostats are specially designed to control combination heating and cooling equipment that operates on line voltage.

These controls are suitable for fans or water solenoids on heating/cooling convectors or any similar application that re- quires a heavy duty room thermostat with single pole, double throw (SPDT) switch action.

DESCRIPTION

W

H

I

T

E-R O DGERS

90

 

70

80

50

60

 

40

NOTE

If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air condi- tioning contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction.

This control has been accurately calibrated at the factory. Any attempt to calibrate this control will void the White-Rodgers warranty.

PRECAUTIONS

!CAUTION

To prevent electrical shock and/or equipment damage disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dan- gerous operation.

Following installation or replacement, follow appli- ance manufacturer’s recommended installation and/ or service instructions to insure proper operation.

!WARNING

Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.

Red

Blue

Common

Open on rise

 

of temperature

WhiteWHITE-RODGERS Close on rise of temperature

SPECIFICATIONS

Electrical Rating

A.C. Motor Rating

120 VAC
240 VAC
Full Load Current7.4 A3.7 A
Locked Rotor Current44.5 A22.2 A
Non-Inductive24 A20 A

These controls have a single pole, double throw (SPDT) snap action switch. The top left-hand terminal (red) is the common terminal. The top right-hand terminal (blue) has open-on-rise switch action. The bottom center terminal (white) has close-on- rise switch action.

WHITE-RODGERS DIVISION

 

PART NO. 37-0885B

EMERSON ELECTRIC CO.

 

9797 REAVIS ROAD

Printed in U.S.A.

Replaces 37-0885A

ST. LOUIS, MISSOURI 63123-5398

 

0017

Page 1
Image 1
White Rodgers 179 specifications Installation Instructions, Operator Save these instructions for future use, Description