WIRING
All wiring must conform to local and national electrical codes and ordinances.
The thermostat may be mounted in any standard 2” x 3” electrical outlet box. For ease of installation use a deep type box.
!CAUTION
USE WITH COPPER CONDUCTORS ONLY.
1.Make electrical connection to thermostat leads with wire nuts or other local code approved devices. All connections must be tight.
Note: Do not push on this knob because calibration will be changed
if knob is bent.
2.Push the lead wires into the outlet box and mount the thermostat to the outlet box with screws provided.
Take care not to push or damage the knob sens- ing element during installation.
3.Snap on the thermostat cover and turn knob to desired setting.
Thermostat
Mounting Screw
BLACK | BLUE | 60 |
70 50
80
LINELOAD
Mounting Screw
Cover