1E65-144
Non-programmable Electronic Digital Thermostat
For Line Voltage Applications
INSTALLATION AND OPERATION INSTRUCTIONS
Operator: Save these instructions for future use!
DESCRIPTION
The
The adapter plate is used to offset the thermostat when an obstruction |
|
prevents the thermostat from being mounted directly to the junction | Temperature |
box. | Display |
The thermostat cannot be used with the following:
-a resistive load under 2 A
-a resistive load over 16.7 A
-systems driven by a contactor or a relay (inductive load)
-central heating systems
Parts Supplied: | Available Accessories: |
One (1) thermostat | |
Two (2) |
|
Temperature
Adjustment
Buttons
Light
Button
System
Switch
SPECIFICATIONS
Supply: 120/240 VAC, 50/60 Hz
Minimum load: 2 A (resistive only) 500 W @ 240 VAC 250 W @ 120 VAC
Maximum load: 16.7 A (resistive only) 4000 W @ 240 VAC 2000 W @ 120 VAC
Setpoint range: | 7°C to 32°C (45°F to 90°F) |
Display range: | 0°C to 37°C (32°F to 99°F) |
Display resolution: | 0.1°C (1°F) |
Shipping: | |
Approval: |
|
PRECAUTIONS
! WARNING
*Failure to read and follow all instructions carefully before installing or operating this control could cause personal injury and/or property damage.
*All wiring must conform to local and national electrical codes and ordinances.
*To prevent electrical shock,personal injury,and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box prior to installation or service.
INSTALLATION
Installation should be done by a qualified heating and air conditioning contractor or licensed electrician.
Loosen the screw holding the thermostat cover to the base, open cover on hinge and remove the cover.
Optional: Use the adapter plate accessory if you need to offset the mounting holes on the junction box. Align and affix the wall plate to the electrical junction box using two
Screw
PART NO. | ||
of Emerson Electric Co. | Replaces | |
0839 |