DESCRIPTION

The 1E65-144 thermostat has been designed to control electric heating systems such as baseboard heaters, radiant floors, radiant ceilings and convectors.

The adapter plate is used to offset the thermostat when an obstruction

 

prevents the thermostat from being mounted directly to the junction

Temperature

box.

Display

The thermostat cannot be used with the following:

-a resistive load under 2 A

-a resistive load over 16.7 A

-systems driven by a contactor or a relay (inductive load)

-central heating systems

Parts Supplied:

Available Accessories:

One (1) thermostat

F61-2642 Adapter Plate

Two (2) 6-32 pan head screws

 

Temperature

Non-programmable Electronic Digital ThermostatFor Line Voltage ApplicationsAdjustment

Buttons

Light

Button

System

INSTALLATION AND OPERATION INSTRUCTIONSOperator: Save these instructions for future use! Switch

SPECIFICATIONS

Supply: 120/240 VAC, 50/60 Hz

Minimum load: 2 A (resistive only) 500 W @ 240 VAC 250 W @ 120 VAC

Maximum load: 16.7 A (resistive only) 4000 W @ 240 VAC 2000 W @ 120 VAC

Setpoint range:

7°C to 32°C (45°F to 90°F)

Display range:

0°C to 37°C (32°F to 99°F)

Display resolution:

0.1°C (1°F)

Shipping:

–20°C to 50°C (-4°F to 120°F)

Approval:

 

PRECAUTIONS

! WARNING

*Failure to read and follow all instructions carefully before installing or operating this control could cause personal injury and/or property damage.

*All wiring must conform to local and national electrical codes and ordinances.

*To prevent electrical shock,personal injury,and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box prior to installation or service.

INSTALLATION

Installation should be done by a qualified heating and air conditioning contractor or licensed electrician.

Loosen the screw holding the thermostat cover to the base, open cover on hinge and remove the cover.

Optional: Use the adapter plate accessory if you need to offset the mounting holes on the junction box. Align and affix the wall plate to the electrical junction box using two 6-32 flat head screws included with the plate.