White Rodgers 1F78 Mounting and Wiring, Electric Heat or Single-Stage Heat Pump Systems

Models: 1F78

1 6
Download 6 pages 43 Kb
Page 2
Image 2

3 REMOVING OLD THERMOSTAT

CONTINUED FROM FIRST PAGE

ATTENTION! This product does not contain mercury. How- ever, this product may replace a unit which contains mercury.

Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing non-absorbent gloves, take up the spilled mercury and place into a container which can be sealed. If a cell becomes damaged, the unit should be discarded.

Mercury must not be discarded in household trash. When the unit this product is replacing is to be discarded, place in a suitable container and return to White-Rodgers at 2895 Harrison Street, Batesville, AR 72501-2117 for proper disposal.

4 MOUNTING AND WIRING

!WARNING

Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.

Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.

Thermostat installation and all components of the sys- tem shall conform to Class II circuits per the NEC code.

Electric Heat or Single-Stage

Heat Pump Systems

This thermostat is configured from the factory to operate a heat/ cool, fossil fuel (gas, oil, etc.), forced air system. It is configured correctly for any system that DOES NOT require the thermostat to energize the fan on a call for heat. If your system is an electric or heat-pump system that REQUIRES the thermostat to turn on the fan on a call for heat, locate the GAS/ELECTRIC switch (see fig. 1) and switch it to the ELECTRIC position. This will allow the thermostat to energize the fan immediately on a call for heat. If you are unsure if the heating/cooling system requires the thermostat to control the fan, contact a qualified heating and air conditioning service person.

Hydronic (Hot Water or Steam)

Heating Systems

This thermostat is set to operate properly with a forced-air heating system. If you have a hydronic heating system (a system that heats with hot water or steam), you must set the thermostat to operate properly with your system.

The factory default setting is forced air heat. Clipping jumper W905 on the circuit board will produce a longer heating cycle which is normally for hot water or steam (hydronic) systems. Both settings produce a very accurate temperature control and can be set to your personal preference. As received, the thermostat cycles the system just under 1˚F. With W905 clipped, the system cycles at approximately 1.5˚F.

!CAUTION

Take care when securing and routing wires so they do not short to adjacent terminals or rear of thermostat. Personal injury and/or property damage may occur.

TERMINAL CROSS REFERENCE CHART

New Thermostat

 

Other Manufacturers’

 

Terminal Designation

 

Terminal Designation

 

RH

4

RH

M

*

*

R5

R

RC

R

R

V

-

-

G

G

G

F

G

G

W

W

W

H

4

W

Y

Y

Y

C

Y6

Y

*These are four-wire, single-transformer systems. Factory installed jumper wire between the RH and RC terminals must remain in place.

Attach Thermostat Base to Wall

1.Remove the packing material from the thermostat. Gently pull the cover straight off the base. Forcing or prying on the thermostat will cause damage to the unit. If necessary, move the electric heat switch (see ELECTRIC HEAT SYSTEMS, above).

2.Connect wires beneath terminal screws on base using appro- priate wiring schematic (see figs. 2 through 7).

3.Place base over hole in wall and mark mounting hole locations on wall using base as a template.

4.Move base out of the way. Drill mounting holes.

5.Fasten base loosely to wall, as shown in fig. 1, using two mounting screws. Adjust until level, and then tighten screws. (Leveling is for appearance only and will not affect thermostat operation.) If you are using existing mounting holes, or if holes drilled are too large and do not allow you to tighten base snugly, use plastic screw anchors to secure subbase.

6.Push excess wire into wall and plug hole with a fire-resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.

Battery Location

This thermostat requires 2 “AAA” alkaline batteries to operate. If “LO BATTERY” is displayed, the batteries are low and should be replaced with fresh “AAA” Energizer® alkaline batteries. To replace the batteries, install the batteries along the top of the base (see fig. 1). The batteries must be installed with the positive(+) ends to the right.

www.white-rodgers.com

Page 2
Image 2
White Rodgers 1F78 Mounting and Wiring, Electric Heat or Single-Stage Heat Pump Systems, Attach Thermostat Base to Wall

1F78 specifications

The White Rodgers 1F78 is a versatile and advanced smart thermostat designed to provide homeowners with optimal control over their heating and cooling systems. As energy efficiency becomes increasingly crucial, the 1F78 incorporates a range of features and technologies that cater to modern comfort needs.

One of the standout characteristics of the White Rodgers 1F78 is its user-friendly interface. The large, backlit display makes it easy to read and navigate, even in low-light conditions. The intuitive controls allow users to set temperature preferences quickly, making adjustments to their comfort levels effortless.

This thermostat is equipped with programmable capabilities, allowing users to set schedules for different days of the week. Homeowners can program the 1F78 to lower temperatures when the house is empty during the day and increase them before they return home. This feature not only enhances convenience but also contributes to significant energy savings over time.

The technology behind the White Rodgers 1F78 includes advanced temperature sensors that ensure accurate readings, leading to efficient temperature regulation. This ensures that the heating and cooling systems only operate when necessary, minimizing energy consumption and costs.

Moreover, the 1F78 is compatible with multiple HVAC systems, including gas, electric, and heat pump systems, making it an ideal choice for various home setups. Its versatility extends to Wi-Fi connectivity, allowing users to monitor and adjust their home's temperature remotely via a smartphone or tablet app. This capability provides homeowners with the convenience of controlling their thermostat from virtually anywhere.

Additionally, the White Rodgers 1F78 features a smart recovery function that learns how long it takes to reach the desired temperature and adjusts the start time accordingly. This ensures that rooms reach the set temperature by the scheduled time without unnecessary overworking of the HVAC system.

In summary, the White Rodgers 1F78 thermostat stands out for its programmable nature, user-friendly interface, compatibility with various HVAC systems, and advanced technologies that optimize energy usage. With its focus on comfort and efficiency, it presents a compelling option for homeowners seeking to enhance their home environment while reducing energy costs.