Figure 3. Typical wiring diagram for heating only,

THERMOSTAT

B O Y G

W RC RH

SYSTEM

Heating

 

 

 

System

 

 

24 VAC Transformer

 

 

 

or

 

 

 

Thermopile

 

 

 

 

B O

NOTE

RED jumper wire (provided with thermostat) must be connected between thermo- stat'sRH and RC terminals for proper thermostat oper- ation with this system.

 

 

 

JUMPER

 

 

 

 

WIRE

 

Y

G

W

RC RH

THERMOSTAT

SYSTEM

 

 

 

 

Cooling

Fan

Heating

 

 

System

Relay

System

 

Hot

 

 

 

24 VAC

120 VAC

 

 

 

 

Neutral

 

 

 

TRANSFORMER

Figure 3. Typical wiring diagram for heating only,

Figure 7. Typical wiring diagram for

2-wire, single transformer systems or millivolt systems

heat/cool, 4-wire, single transformer systems

Thermostat

R W

 

NOTE

 

 

 

Jumper wire must

be

 

added between R and B

3-wire Series 10

terminals on the primary

Primary Control

control (jumper wire

not

(located at furnace)

provided with thermostat.

 

 

 

 

B

 

 

 

 

 

 

 

 

W

 

 

 

 

R

 

 

 

 

Furnace

Add jumper wire

(not provided with thermostat)

THERMOSTAT

B O Y

G

W

RC RH

Cooling

Fan

Heating

System

Relay

System

SYSTEM

Hot

24 VAC

120 VAC

Neutral

HEATING TRANSFORMER

 

Hot

24 VAC

120 VAC

Neutral

COOLING TRANSFORMER

Figure 8. Typical wiring diagram for

Figure 4. Typical wiring diagram for 3-wire SERIES 10 heating systems

heat/cool, 5-wire, two-transformer systems

JUMPER

JUMPER

B O Y

NOTE

RED jumper wire (provided with thermostat) must be connected between thermo- stat'sRH and RC terminals for proper thermostat oper- ation with this system.

JUMPER

WIRE

G

W

RC

RH

THERMOSTAT

SYSTEM

 

 

 

 

Fan

Heating

 

 

 

Relay

System

 

 

Hot

 

 

 

24 VAC

120 VAC

 

 

 

 

Neutral

 

 

 

TRANSFORMER

 

WIRE

B O

Y

G W

Changeover

Compressor

Fan

Relay*

Contactor

Relay

*Changeover relay is energized when the system switch is in the COOL position

WIRE

THERMOSTAT

RC RH

SYSTEM

Hot

24 VAC

120 VAC

Neutral

TRANSFORMER

Figure 9. Typical wiring diagram for

heat pump with cool active changeover relay

Figure 5. Typical wiring diagram for

heat only, 3-wire, single transformer systems

B

O

Y

G W RC RH

THERMOSTAT

SYSTEM

 

 

 

 

 

 

Cooling

Fan

 

 

 

System

Relay

Hot

 

 

 

24 VAC

120 VAC

 

 

JUMPER

 

 

WIRE

B

O

Y

G W

Changeover

Compressor

Fan

Relay*

 

Contactor

Relay

*Changeover Relay is energized when the system switch is in the HEAT position

JUMPER

WIRE

THERMOSTAT

RC RH

SYSTEM

 

 

 

 

 

 

Hot

 

 

 

 

 

 

 

24 VAC

 

 

 

 

120 VAC

 

 

 

 

 

 

 

Neutral

TRANSFORMER

Neutral

TRANSFORMER

Figure 6. Typical wiring diagram for

cool only, 3-wire, single transformer systems

Figure 10. Typical wiring diagram for

heat pump with heat active changeover relay